Substation power transformer
3.6 - 12 kV | YBM(P) 29-12/0.4
Chint Electric Co.,Ltd.
YBM(P) 29-12/0.4 Ordinary Prefabricated Substation
Application: The substation consisted of HV switchgears, transformer, LV switchgear supplied all by CHINT to receive and distribute power energy in distribution system of high-rise buildings, residential areas, factories, parks, etc.
Standards: IEC1330
Parameters:
Rated voltage: high voltage side: 3.6-12kV, low voltage side: 0.4kV.
Rated current: high voltage side: 630A, low voltage side: 100-3200A.
Rated capacity: 50-2X1600kVA and below.
Features:
Designed to perfectly match with the sceneries around.
Compact design.
High security and reliability in operation.
Easy maintenance and movable for convenient installation.
Customized substations are available on your requirement.
Technical Data:
Rated voltage (kV):
- HV Apparatuses: 7.2/12
- Transformer: 6/0.4, 10/0.4
- LV Apparatuses: 0.4
Rated capacity (kVA):
- Transformer: 200~1250/50~800
- LV Apparatuses: Max. 2×1600
Rated current (A):
- HV Apparatuses: 200~630
- LV Apparatuses: 100~3000
Rated breaking current (A):
- HV Apparatuses: Load switch: 400~630A
- LV Apparatuses: 15~63
Rated short-time withstands current /s (kA):
- HV Apparatuses: Load switch: 20×(2), 20×(2)
- Transformer: 200~400kVA
- LV Apparatuses: 15×1, 30×1
* All the data are only examples for your reference.
* Customized products are available according to your requirements.
Application: The substation consisted of HV switchgears, transformer, LV switchgear supplied all by CHINT to receive and distribute power energy in distribution system of high-rise buildings, residential areas, factories, parks, etc.
Standards: IEC1330
Parameters:
Rated voltage: high voltage side: 3.6-12kV, low voltage side: 0.4kV.
Rated current: high voltage side: 630A, low voltage side: 100-3200A.
Rated capacity: 50-2X1600kVA and below.
Features:
Designed to perfectly match with the sceneries around.
Compact design.
High security and reliability in operation.
Easy maintenance and movable for convenient installation.
Customized substations are available on your requirement.
Technical Data:
Rated voltage (kV):
- HV Apparatuses: 7.2/12
- Transformer: 6/0.4, 10/0.4
- LV Apparatuses: 0.4
Rated capacity (kVA):
- Transformer: 200~1250/50~800
- LV Apparatuses: Max. 2×1600
Rated current (A):
- HV Apparatuses: 200~630
- LV Apparatuses: 100~3000
Rated breaking current (A):
- HV Apparatuses: Load switch: 400~630A
- LV Apparatuses: 15~63
Rated short-time withstands current /s (kA):
- HV Apparatuses: Load switch: 20×(2), 20×(2)
- Transformer: 200~400kVA
- LV Apparatuses: 15×1, 30×1
* All the data are only examples for your reference.
* Customized products are available according to your requirements.
-
zoom