Temperature alarm


Functions and display

- Alarm Indicator
The indicator shows, which time/tempera-ture conditions have been violated. The first violated condition is shown in the first column. All further violated conditions will be shown in the second column.
- Time Conditions
The transportation time, programmed between 1 to 48 days according to customer requirements, is subdivided into 24 time segments.
Example:
one time segment: 6 hours
total transportation time: 6 days
- Alarm Time Indicator
The arrow together with the word ALARM shows when the alarm conditions have been violated. (in which time segment after the start)
- Measurement Zones
The time/temperature parameters can be programmed according to customer requirements. (cumulative or single event)
Example:
21°C Alarm after 72h
>34°C Alarm after 2h