Medium voltage overcurrent protection relay
FANOX ELECTRONIC
Overcurrent and Earth Fault potection relay SIL - A
* Sil a lado webProtection functions by default: 2x50P, 2x50N, 5xP, 51N, 50BF, 46, 52, 79, 74TCS, COLD LOAD PICK-UP
* With standard current transformers /5 or /1, or special low power current transformers (LPCT)
* Metallic Box with high EMC (Electromagnetic compatibility) and wide range of operating temperature
* Reduced size and light weight
* Direct signaling/control of circuit breaker (52 function) and recloser (79 function)
* External magnetic module for the /1 or /5: easy to withdraw, more reliability, simplifies the assembly and reduces maintenance costs of switchgear...
* 2 communication protocols simultaneously: Mod Bus & IEC60870-5-103
* 8 inputs and 6 outputs configurable, trip coil supervision (74TCS function)
*Oscillography, 20 fault reports and non-volatile RAM memory: 500 events can be recorded and stored even without power supply, keeping the current date and time thanks to its internal RTC
* We are able to give you added value to your switchgear including several options (arc protection sensors, SF6 gas detection sensors...)
BATTERY FEED KitCom
* Adaptor that lets you connect two batteries AAA type of 1,5V to the SIL relays using the front RS232 communications port.
* The adaptor allows the use of a 12V battery power supply and communication through the port at the same time.
* ensures full operability of the SIL, even when tripping in case of a fault.
* Sil a lado webProtection functions by default: 2x50P, 2x50N, 5xP, 51N, 50BF, 46, 52, 79, 74TCS, COLD LOAD PICK-UP
* With standard current transformers /5 or /1, or special low power current transformers (LPCT)
* Metallic Box with high EMC (Electromagnetic compatibility) and wide range of operating temperature
* Reduced size and light weight
* Direct signaling/control of circuit breaker (52 function) and recloser (79 function)
* External magnetic module for the /1 or /5: easy to withdraw, more reliability, simplifies the assembly and reduces maintenance costs of switchgear...
* 2 communication protocols simultaneously: Mod Bus & IEC60870-5-103
* 8 inputs and 6 outputs configurable, trip coil supervision (74TCS function)
*Oscillography, 20 fault reports and non-volatile RAM memory: 500 events can be recorded and stored even without power supply, keeping the current date and time thanks to its internal RTC
* We are able to give you added value to your switchgear including several options (arc protection sensors, SF6 gas detection sensors...)
BATTERY FEED KitCom
* Adaptor that lets you connect two batteries AAA type of 1,5V to the SIL relays using the front RS232 communications port.
* The adaptor allows the use of a 12V battery power supply and communication through the port at the same time.
* ensures full operability of the SIL, even when tripping in case of a fault.
-
zoom