NDIR combustion, environmental and emission gas analyzer
Enox
Fer Strumenti
The Enox multicomponent gas analyzer is an industrial photometer based on the non dispersive photometry in the infrared, for the contemporary measure of several gases.
The technology which has been used is based on correlation filters (GFC) and optical non dispersive absorption (DOAS). A high stability sensor, working at a very low temperature (-35 °C) and the used technology ensure a nearly fully immunity to cross sensitivity, high stability and sensitivity.
A very powerful electronic unit that can acquire all available measures (4000 per second for each analyzed gas) reduces the noise to a minimum value.
The measuring principle, the optical bench and the automatic and accurate compensation of the variations of room temperature enable to avoid the expensive and complicated automatic calibrations, which are always possible.
A large back lighted graphic display continuously supplies the value of the measured gases (including a large bar graph), the alarms, the service requirements, the faults, separated for each gas and the alarms from the sampling system.
All alarms have the acknowledgement routine. All anomaly messages are reported on the display for the immediate knowledge of what has gone wrong. Contacts enable to retransmit all the diagnostic.
This instrument has been drawn to be user friendly and reduce as much as possible the costs of the analysis system in which it will be used. The analyzer can be directly connected to a P.C. provided with a special software, named DAS-DAC, for data acquisition.
The technology which has been used is based on correlation filters (GFC) and optical non dispersive absorption (DOAS). A high stability sensor, working at a very low temperature (-35 °C) and the used technology ensure a nearly fully immunity to cross sensitivity, high stability and sensitivity.
A very powerful electronic unit that can acquire all available measures (4000 per second for each analyzed gas) reduces the noise to a minimum value.
The measuring principle, the optical bench and the automatic and accurate compensation of the variations of room temperature enable to avoid the expensive and complicated automatic calibrations, which are always possible.
A large back lighted graphic display continuously supplies the value of the measured gases (including a large bar graph), the alarms, the service requirements, the faults, separated for each gas and the alarms from the sampling system.
All alarms have the acknowledgement routine. All anomaly messages are reported on the display for the immediate knowledge of what has gone wrong. Contacts enable to retransmit all the diagnostic.
This instrument has been drawn to be user friendly and reduce as much as possible the costs of the analysis system in which it will be used. The analyzer can be directly connected to a P.C. provided with a special software, named DAS-DAC, for data acquisition.
-
zoom