The general purpose non-intrusive capacitance level switch provides reliable liquid level detection of water based conductive liquids with non-coating and/or scaling characteristics with a 1A relay output. Media examples include hydrochloric, sulfuric acid and water. The liquid level sensor is bracket mounted on the exterior wall of non-metallic tanks and applied as a high level alarm or low level alarm.
FEATURES
Non-intrusive level detection through plastic or fiberglass walls
Installed with PE, PP or PVDF adhesive 3M mounting brackets
Rugged PSO enclosure rated NEMA 4X with conduit connector
60VA relay selectable NO or NC via power supply wiring polarity
Accuracy: ± 1mm in water
Repeatability: ± 0.5mm in water
Dielectric range: > 10 constants
Conduct. range: > 100 μ
Supply voltage: 12-36 VDC
Consumption: 25 mA maximum
Contact type: (1) SPST relay
Contact rating: 60 VA, 1A maximum
Contact output: Selectable NO / NC
Enclosure rating: NEMA 4X (IP65)
Enclosure mat.: PSO
Cable jack. mat.: Polypropylene
Cable type: 4-conductor, shielded #22 AWG
Cable length: 10’ (3m)
Conduit entrance: 1/2” NPT
Tank mat. comp.: Non-metallic
Tank mounting: Bracket w/3M adhesive, plastic thermal weld
Tank wall thickness: < 1” (25mm)
Bracket material: -6005: Polyethylene, -1005: Polypropylene, -5005: PVDF
Classification: General purpose
Compliance: CE