Custom induction coil
FluxTrol
Application: Case Harden S-Cam and Shaft
Original Concentrator: None
Problem / Failure Mode: Extended Cycle Times / Loss of Pattern Control
Power Supply: 150 kW (135 kW in use), 3–10 kHz (7 kHz in use)
Problem / Solution:
Customer not satisfied with cycle times
Customer experiencing loss of pattern control
Coil and application reviewed for pattern and time
Optimized coil design via computer simulation
New coil design utilizes Fluxtrol A material
Tests meet spec and coil returned to production
Fluxtrol Advantage: Cycle Time Reduced 46% with Pattern Improvement!
Original Concentrator: None
Problem / Failure Mode: Extended Cycle Times / Loss of Pattern Control
Power Supply: 150 kW (135 kW in use), 3–10 kHz (7 kHz in use)
Problem / Solution:
Customer not satisfied with cycle times
Customer experiencing loss of pattern control
Coil and application reviewed for pattern and time
Optimized coil design via computer simulation
New coil design utilizes Fluxtrol A material
Tests meet spec and coil returned to production
Fluxtrol Advantage: Cycle Time Reduced 46% with Pattern Improvement!
-