variable-area flow meter / for gas / for water / direct-reading
GR-065 GHM Messtechnik GmbH

{{requestButtons}}

Characteristics

  • Technology:

    variable-area

  • Fluid:

    for gas, for water

  • Other characteristics:

    direct-reading, glass tube, top-mounted, stainless steel

  • Process pressure:

    12 bar (174.05 psi)

  • Process temperature:

    Max.: 90 °C (194 °F)

    Min.: -20 °C (-4 °F)

  • Volumetric flow rate:

    Max.: 43.3 l/min (11.4 us gal/min)

    Min.: 0 l/min (0 us gal/min)

Description

Minimum measurement quantity
●Convex cut for enlargement
●Optionally valve
●Good resistance to medium
CharacteristicsA float moves in a transparent conical measurement tube, relative
to the flow. The position of the float depends on the volume flow (weight force versus resistance to flow), and indicates the flow rate on the scaled measurement tube