Hydrogen leak detector / intrinsically safe
HY-ALERTA 1600 H2scan

H2scans HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogens low flammability limit. H2scan's hydrogen-specific sensor technology has no cross sensitivity to other combustible gases, thus eliminating false positive alarms.

Performance
Hydrogen Sensitivity Range:
0.4% to 5% hydrogen by volume
10% to 125% hydrogen lower flammable limit
Accuracy: ± (0.03 x indication + 0.2) percent hydrogen by volume
Typical Response Time: T90 of 60 sec maximum
Ingress Protection: IP64 capable
Calibration Interval: 90 days
Product Life Expectancy: 10 years

Interface Options
Power Barrier Input Voltage: 24 VDC nominal
Power Barrier Input Voltage Range: 20 VDC to 28 VDC
Intrinsically Safe Sensor Input Voltage: 10 VDC
Sensor Input Voltage Range: 5 VDC to 28 VDC
Input Power: 10 W
Analog Outputs: 4 mA to 20 mA
Serial Communication: RS422

Operating Conditions
Operating Humidity: 0% to 95% RH
Operating Temperature Range: -20ºC to 40ºC
Storage Temperature Range: -40ºC to 50ºC
Calibration Background Gas: Air
Included Accessories
Intrinsically Safe Power Barrier
4 m Power / Analog Cable

Optional Accessories
Intrinsically Safe Analog Output Barrier
Intrinsically Safe Serial Interface Barrier
4 m RS422 Serial Interface Cable

Dimensions
Total Length: 8.1 in.
Total Width: 4.4 in.
Depth: 1.6 in.

{{requestButtons}}
Favorites

Other H2scan products