Electric XY stage ITK Dr Kassen
Cross table with a large working range.
Stepper Motor Controller integrated.
Plug an play capability, easy to operate.
Application:
Positioning stages for measurement and analytical systems
Technical data:
Working range (X / Y): .....450 x 390 mm
Size: (HxBXW): ................126 x 640 x 580 mm
Drive system:....................Stepper Motor ( Pollux Controller)
Measurement system: .....optical or. magnetically
Limits: .......................... ...precise Hall limit switches
Host Interface: ................ RS-232 / CAN-Bus
Power: .............................24V
Velocity: ...........................up to 80mm/s
Acceleration: ....................up to 250mm/s²
Resolution: ......................1µm
Repeatability: ..................+/- 3µm
Accuracy: .........................+/- 20µm
Weight: ...........................16 kg