Explosion proof solenoid for solenoid valves
24 - 230 V AC/DC, max. 15 W, ATEX JAKSA

Solenoids JAK0A TMEx35/A/B/C/D and TMEx40/A/B/C/D are intended for use as actuators with JAK0A solenoid valves. These solenoids can be used in hazardous areas zone 1 and 2 (presence of explosive gas, vapour and mist).

Mark of protection: II 2G Ex e mb II T4/T5 Gb
Approval number: SIQ 10 ATEX 183X
Type of explosion protection: "encapsulation" + "increased safety"

Conformity with standards: Directive 94/9/EC (ATEX); EN 60079-0:2006; EN 60079-18:2004; EN 60079-7:2007

Electrical connection: built-in terminal Ex e I/II
Cable gland: Ø 6.5 - 12 mm II 2G Ex e II IP 66/67 (M20x1.5)
Grounding: inner and outer grounding bolts galvanically binded to metallic
part of solenoid
Coil wire insulation class: H 180°C
Protection of enclosure: IP65 (IEC 529)
Fuses: thermal 115°C, 3 A + cartridge 1 A