Digital pyrometer CellaTemp® PA 29
°Canalog outputIP65

Digital pyrometer - CellaTemp® PA 29 - Keller Pyrometer Systems - °C / analog output / IP65
Digital pyrometer - CellaTemp® PA 29 - Keller Pyrometer Systems - °C / analog output / IP65
Digital pyrometer - CellaTemp® PA 29 - Keller Pyrometer Systems - °C / analog output / IP65 - image - 2
Digital pyrometer - CellaTemp® PA 29 - Keller Pyrometer Systems - °C / analog output / IP65 - image - 3
Add to favorites
Compare this product

Characteristics

Display
digital
Units of measurement
°C
Communication
analog output
Protection level
IP65
Configuration
fixed
Applications
industrial, for metals
Other characteristics
precision, special, for low emissivity, optical
Temperature

Min.: 150 °C
(302 °F)

Max.: 800 °C
(1,472 °F)

Spectral range

Min.: 1.8 µm

Max.: 2.2 µm

Response time

Min.: 2 ms

Max.: 75 ms

Description

Product overview
The CellaTemp® PA 29 is an industrial infrared pyrometer with a special blocking filter and photodiode sensor designed to minimise influence from daylight, laser radiation and reflected hot-object radiation. With multiple optical variants and broad measuring ranges, it is particularly suited to temperature measurement on aluminium and other low-emissivity metals at low to very high temperatures.

Key features
  • Measuring ranges (examples): 150–800 °C; 180–1200 °C; 250–2000 °C; 350–2500 °C
  • Focusable lens for precise adjustment of measuring distance
  • Broadband anti-reflective precision optics
  • Optimised for metallic surfaces and low emissivity materials
  • Large, remote-readable LED display
  • Test current output for diagnostics
  • Standard interfaces: digital I/O, two analogue outputs (0/4–20 mA), USB and RS‑485


Available versions / options
CellaTemp PA 29 AF 10; CellaTemp PA 29 AF 1; CellaTemp PA 29 AF 2; CellaTemp PA 29 AF 3; CellaTemp PA 29 AF 4; CellaTemp PA 29 AF 5; CellaTemp PA 29 AF 6; CellaTemp PA 29 AF 21; CellaTemp PA 29 AF 22; CellaTemp PA 29 AF 23

Technical data
  • Sensor: photodiode · Spectral range: 1.8–2.2 µm
  • Measuring ranges (examples): 150–800 °C; 180–1200 °C; 250–2000 °C; 350–2500 °C
  • Response time t98: down to ≤ 2 ms depending on range (examples in product documentation)
  • Measurement uncertainty: 0.75 % of reading (150–1200 °C ranges) or 0.5 % of reading (250–2500 °C ranges); minimum offsets apply
  • Repeatability: 1 K · Temperature coefficient: 0.25 K/K (T < 500 °C) / 0.05 %/K (T > 500 °C)
  • Resolution: display and interface resolutions down to 0.1 K depending on range


Optical variants (lenses)
  • 150–800 °C: Objective F50 PZ 20.08 focusing 0.3 m–∞
  • 180–1200 °C: Standard lens PZ 20.01 (0.4 m–∞); Close-up PZ 20.03 (0.2–0.4 m); Telephoto PZ 20.06 (1.2 m–∞)
  • 250–2000 °C and 350–2500 °C: Standard PZ 20.01; Close-up PZ 20.03; Wide-angle PZ 20.05; Telephoto PZ 20.06


Electrical parameters
  • Analogue outputs: 0(4)–20 mA (linear, switchable, scalable); max. load ≤ 500 Ω
  • Analogue input: 0–10 V
  • Switching outputs: 2 × open collector 24 V DC, ≤ 30 mA
  • Switching inputs: 2 × up to 24 V
  • Interfaces: USB, RS‑485 · Power supply: 24 V DC (+10 % / −20 %)


Camera / sighting options
  • Video output (for camera model): composite PAL
  • Sighting: through-the-lens sighting, laser pilot light, video camera


Display, control & measuring principle
  • Display: 4‑digit red LED (8 mm digits) · Status: 2 × LED · Controls: 3 buttons
  • Measuring principle: single-colour infrared


Mechanical & environmental
  • Housing: stainless steel V2A (1.4305) · Protection class: IP65
  • Dimensions: Ø 65 mm × 220 mm (max. 277 mm) · Weight: approx. 0.9 kg
  • Ambient temp.: 0–65 °C · Storage temp.: −20–+80 °C · Permissible humidity: ≤ 95 % r.H. (non‑condensing)


Adjustable parameters (selection)
  • Measuring range and measured variable scaling
  • Smoothing filter; memory and hold time; emissivity; transmittance
  • Compensation of reflected ambient radiation; alarm limits and modes
  • ATD function parameters (optional); linearization; LED status behaviour; simulation modes; °C/°F


Functions (selection)
  • Overtemperature signal (if internal temperature > 80 °C analogue output > 20.5 mA)
  • Service function: simulation of measured value or current signal
  • ATD (Automatic Temperature Detection) for discontinuous processes


Scope of delivery
  • Pyrometer CellaTemp PA
  • Connection cable VK 02/A (5 m)
  • Video cable VK 02/F (5 m) for models with camera
  • USB cable VK 11/D (1.8 m)
  • Software CellaView · Short manual


Technical specifications summary
  • Model: CellaTemp® PA 29 · Measuring principle: single-colour infrared pyrometer
  • Spectral range: 1.8–2.2 µm · Sensor: photodiode
  • Measuring ranges: 150–800 °C; 180–1200 °C; 250–2000 °C; 350–2500 °C
  • Response time: down to ≤ 2 ms depending on range · Typical accuracy examples: 0.75 % or 0.5 % of reading
  • Outputs: 0(4)–20 mA (2 outputs) · Interfaces: USB, RS‑485 · Power: 24 V DC
  • Housing: stainless steel, IP65 · Optional sighting: through-the-lens, laser, video camera

Catalogs

No catalogs are available for this product.

See all of Keller Pyrometer Systems‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

HärtereiPraxis 2026
HärtereiPraxis 2026

22-24 Jun 2026 Kamp-Lintfort im Wellings Parkhotel (Germany)

Shenzhen International Semiconductor &amp; IC Exhibition
Shenzhen International Semiconductor &amp; IC Exhibition

9-11 Sep 2026 Shenzhen (China)

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.