KEM Küppers Elektromechanik GmbH

Gear flow-meter for hot-melt
KEM Küppers Elektromechanik GmbH

The Dispense Control Device (DCD)

includes a gear dosing pump with a gear flow meter incorporated into the connector block, which measures the actual flow rate and provides a corresponding output signal. This way the set point can be constantly adjusted and permanently monitored, even at small deviations.

Compact design and small manufacturing tolerances ensure a high degree of accuracy. The operating range of the DISPENSE CONTROL DEVICE is 0.005 to 2 ltr./min and can be adjusted with a tolerance of ± 0.5%. DISPENSE CONTROL DEVICES for higher flow rates are available upon request.

Technical Data - ZHM measuring cell
• Dosing range: 0.005 to 2 l/min
• Measuring accuracy: ± 0.5% of actual value
• Repeatability: 0.1%
• Pulse rate: approximately 26,500 pulses/l
• Operating pressure: max. 40 bar

Technical Data - Gear pump
• Output: 0.3 to10.0 cm³/U
• Lip seal and buffer fluid reservoir
• r.p.m: 10 min up to 200 min-1, depending on the pumped medium
• Standard rotation direction: right, left
• Terminal block: G1/4’’; 3/8“; 1/2“
• Drive shaft: Ø 12mm
• Weight: approx. 2.5 kg
  • zoom



standListOtherProduct www di En 2012-02-07-14