Turbidity meter
150 - 4 000 NTU | KPS
KEM Küppers Elektromechanik GmbH
Optical turbidity meters (KPS)
are used to optimize industrial production processes and are particularly suitable for liquid foods. The optical sensors detect and analyze even the slightest changes in product composition of various liquids.
An output signal of 4 to 20 mA depending on the turbidity level is available to the user for process control purposes. Due to a wide range of process interfaces, the device can be used in the pharmaceutical and food industry.
Technical Data:
* Measuring ranges: approx. 150 - 4,000 NTU
* Linearity: ± 0.2% of final value
* Repeatability: ± 1% of final value
* Maximum pressure: up to 14 bar
* Temperature
- Environment: 0 to +50°C
- Process: 0 to +100°C
- CIP cleaning: 0 to +150°C
are used to optimize industrial production processes and are particularly suitable for liquid foods. The optical sensors detect and analyze even the slightest changes in product composition of various liquids.
An output signal of 4 to 20 mA depending on the turbidity level is available to the user for process control purposes. Due to a wide range of process interfaces, the device can be used in the pharmaceutical and food industry.
Technical Data:
* Measuring ranges: approx. 150 - 4,000 NTU
* Linearity: ± 0.2% of final value
* Repeatability: ± 1% of final value
* Maximum pressure: up to 14 bar
* Temperature
- Environment: 0 to +50°C
- Process: 0 to +100°C
- CIP cleaning: 0 to +150°C
-
zoom