Explosion proof remote temperature controller
Command Ex i - II 2G EEx ia IIC T4
LAUDA DR. R. WOBSER GMBH & CO. KG
Explosion-proof
Command Ex i remote control
LAUDA offers the Command remote control as an explosion-proof version. The intrinsically safe design of the control panel is authorised for explosion protection II 2G EEx ia IIC T4.
The modular nature of LAUDA devices means that the Command remote control can be used with the LAUDA Integral XT, Proline Kryomats, Proline and ECO devices. The thermostats themselves are set up outside of the ex-zone.
In addition to the actual remote control, two barrier boxes are also supplied, which are connected between the device and the control panel in order to ensure that the electrical currents are limited. The barrier boxes connected
to the thermostat are connected to the Command and optionally to a sensor, which can be used as an external temperature gauge. Possible sensors would
be a Pt100 resistance thermometer or a 4-20 mA temperature sensor.
LRT 915 Command Ex i remote control including 10 m cabel and barrier box
LRT 916 Command Ex i remote control including 50 m cabel and barrier box
LRT 917 Barrier box external sensor including 4-20 mA connection
LRT 918 Barrier box external sensor including Pt100 connection
LRT 919 Barrier box external sensor including 2 4-20 mA connections
LRT 920 Barrier box external sensor including 4-20 mA connection and Pt100 connection
Command Ex i remote control
LAUDA offers the Command remote control as an explosion-proof version. The intrinsically safe design of the control panel is authorised for explosion protection II 2G EEx ia IIC T4.
The modular nature of LAUDA devices means that the Command remote control can be used with the LAUDA Integral XT, Proline Kryomats, Proline and ECO devices. The thermostats themselves are set up outside of the ex-zone.
In addition to the actual remote control, two barrier boxes are also supplied, which are connected between the device and the control panel in order to ensure that the electrical currents are limited. The barrier boxes connected
to the thermostat are connected to the Command and optionally to a sensor, which can be used as an external temperature gauge. Possible sensors would
be a Pt100 resistance thermometer or a 4-20 mA temperature sensor.
LRT 915 Command Ex i remote control including 10 m cabel and barrier box
LRT 916 Command Ex i remote control including 50 m cabel and barrier box
LRT 917 Barrier box external sensor including 4-20 mA connection
LRT 918 Barrier box external sensor including Pt100 connection
LRT 919 Barrier box external sensor including 2 4-20 mA connections
LRT 920 Barrier box external sensor including 4-20 mA connection and Pt100 connection
-