Weight indicator for Omega/DIN-rail mounting
LAUMAS Elettronica
Weight indicator for Omega/DIN rail mounting, suitable for front panel, back
panel and junction box. Dimensions: 106 x 110 x h 60 mm (including extractable terminal boards). Six-digit semialphanumeric display (14 mm h),7 segment LED. Five-key membrane keyboard. IP54 front panel protection.
Serial Outputs for connection to:
- PC/PLC by Laumas Protocol and ModBus RTU Protocol (rs232 or
rs422/485) or Profi bus DP (rs422-485).
- Remote display (rs232 or 422).
- Printer and/or RD data recorder (rs232).
PASSWORD to protect the access to selected functions.
THEORETICAL CALIBRATION is performed via the keyboard.
READING THE LOAD CELLS VALUE expressed in mV.
CHECKING THE LOAD CELLS CONNECTION with safety function (dropout
relays).
Main functions
- 4 set-points confi gurable as normally open or normally closed. The operator can decide the setpoints activation for the net weight value, gross weight value, or according to the peak value, otherwise for positive weights or for positive and negative weights.
- Selection of hysteresis values for every set-point.
- Peak Holder visualization by closing the relative input contact.
- Print of the weight via keyboard or external contact with date and time.
- Net/Gross function by keyboard or external contact.
- Auto zero function.
panel and junction box. Dimensions: 106 x 110 x h 60 mm (including extractable terminal boards). Six-digit semialphanumeric display (14 mm h),7 segment LED. Five-key membrane keyboard. IP54 front panel protection.
Serial Outputs for connection to:
- PC/PLC by Laumas Protocol and ModBus RTU Protocol (rs232 or
rs422/485) or Profi bus DP (rs422-485).
- Remote display (rs232 or 422).
- Printer and/or RD data recorder (rs232).
PASSWORD to protect the access to selected functions.
THEORETICAL CALIBRATION is performed via the keyboard.
READING THE LOAD CELLS VALUE expressed in mV.
CHECKING THE LOAD CELLS CONNECTION with safety function (dropout
relays).
Main functions
- 4 set-points confi gurable as normally open or normally closed. The operator can decide the setpoints activation for the net weight value, gross weight value, or according to the peak value, otherwise for positive weights or for positive and negative weights.
- Selection of hysteresis values for every set-point.
- Peak Holder visualization by closing the relative input contact.
- Print of the weight via keyboard or external contact with date and time.
- Net/Gross function by keyboard or external contact.
- Auto zero function.
-