Application - Monitoring of safety functions
Functions - 3 Industrial Ethernet protocols on-board: PROFINET, EtherNet IP, Modbus TCP
4 configurable safe I/Os (via software)
24 safe I/Os
40 certified function modules
Configuration via mini USB or Ethernet (TCP/IP)
Expandable with up to 12 I/O modules
Freely configurable with MSI.designer (license-free)
Modularly expandable safety control
Program memory in SD card format (512 MB)
Switching current 4 A per output
Transfer of diagnostic data via external fieldbus gateways
Up to 300 function modules in a project
SIL - 3, IEC 61508
SILCL - 3, IEC/EN 62061
Performance Level (PL) - Up to and including e, EN ISO 13849-1
PFHD - 4,3E-09 per hour
Mission time - 20 years, EN ISO 13849-1
Category - 4, EN ISO 13849
Supply voltage UB - 24 V, DC, -30 ... 25 %
Power consumption, max. - 3.3 W
Number of outputs - 4 Piece(s)
Number of configurable inputs/outputs - 4 Piece(s)
Type of digital output - Transistor
Short circuit protection, outputs - Yes
Nominal output current per output, max. - ≤ 12 A / 8 ms
Number of inputs - 16 Piece(s)
Voltage permitted at the input - HIGH: 13 … 30 V
LOW: -5 … +5 V
Input current at signal 1 - HIGH: typ. 2.3 mA / max. 6 mA
LOW: < 2
Type - Ethernet, USB
Function - Configuration via software
Function - Configuration via software
Number of connections - 3 Piece(s)
Function - Signal IN
Signal OUT
Voltage supply
Type of connection - Terminal
Type of terminal - Spring-cage terminal
No. of pins - 32 -pin
Function - Configuration interface
Function - BUS OUT
Connection cross sections - 2 x 0.2 to 1.5 mm², wire
2 x 0.25 to 1.5 mm², wire with wire-end sleeve (pressed in trapezium shape)