LITRE METER

Positive displacement flow-meter
0 - 16 500 l/min, 0.8 - 1000 000 cSt, IP 68 | V270 LITRE METER

  • positive displacement flow-meter 0 - 16 500 l/min, 0.8 - 1000 000 cSt, IP 68 | V270 LITRE METER
Positive displacement flowmeter with 316 stainless steel body, providing a pulse output. Nitronic SS, brass or carbon graphite rotor dependent on pressure and flow rate range. Hazardous area approved as standard.
Flow range : 0 to 16,500 l/hr. Minimum subject to fluid viscosity e.g. 1500 l/hr on 11cSt. 33,000 l/hr with AGPVD option.
Liquid : Any non abrasive, chemical compatible clean liquid. 0.8 to 1,000,000 cSt. For higher viscosities up to 2000 cSt a reduced maximum flow rate may apply.

Accuracy :
- ±1% reading - linearity.
- ±0.5% reading - with linearisation
- ±0.25% repeatability.

Pressure/ Temperature :
Pressures up to 40 bar and above (max 690bar), temperature from -40 to +150°C. IP68.

Features :
Simple construction with only one moving part and reed switch pulse output. Available with any end connections to suit your application. Female NPT threaded connections standard, wafer fit, hubs available.



standListOtherProduct www di En 2012-05-22-30