Filter cartridge for chemical and polymer applications
5 - 100 µm | 1602, 1603 series
Maag Pump Systems
2. Pressure drop calculations based on 20 micron elements.
3. Element length is for mesh pack and does not include end fitting.
4. Polymer viscosity is 250 Pas (2500 Poise).
5. Design conditions are 241.5 Bar (3500 psi) and 343.5C (650F).
6. Vessel material is 304SS and system is designed per ASME Code.
7. System configuration is MPST's patented close-coupled design.
8. System includes manual vent valves and hydraulically automated diverter valves with control panel.
9. System prices are Ex Works Maag Factory.