Aries1003 is the right solution for the VOCs emission monitoring, in term of accuracy, simplicity and analytical stability.
Compact and complete:
• - FID detector and automatic pressure regulators driven by software.
• - Industrial integrated PC equipped with Windows® OS.
• - Touch screen display interface.
• - Methane analytical kit with packed columns.
Integrated PC embedded technology:
The industrial PC housed in the analyser, in addition to monitor and control the Detector, the thermoregulation and every operation, has the task of Data logger and saves the analysis in an Excel® compatible format file. The Windows Embedded® operating system with his advanced software, guides and supports you at all times. Every fault is detected and stored.
We use sampling valve with no mechanical moving parts, able to guarantee two exclusives advantages despite the classic calibrated capillaries technology.
• - More analytical stability.
• - Less maintenance frequency.
Methane analysis performed via packed column directly housed into the instrument. Doesn’t need any bulky and/or expensive accessory.
The catalyst analysis is carried out in accordance with European standard EN 25140:2010
Sample suction systems and vacuum sensors
Aries uses an ejector system (no maintenance required).
Both analysers are equipped with a vacuum sensor which generate an alarm if any leakage or filter clogging condition occur.
Normative References:
• - EN 12619 – for the analysis of VOCs.
• - EN 15267-3/4 – for the analysis of VOCs.
• - EN 14181 – QAL1