A. Machine
- Miracle787 MACHINE
- RENISHAW UCC Lite Control System
- Calibrate Ball with Support Base
- User and System Manuals
B. Computer System
- Minimum configuration: Pentium ¥³3.0 GHz/512MB RAM/80GB Hard Disk/32MB Graphic Card /17¡ÈColor LCD Monitor/ Window¡¯s OS
- HP Color DeskJet printer
C. Software System
-Amereican Rantional DMIS software(for Windows XP)
DMiracle 787 Performance Specifications
Measuring Strokes :700(mm) x800(mm) x 700(mm)
Overall Dimension : 1600(mm) x 1950(mm) x3000 (mm)
Max part weight : 1000 kg
Resolution : 0.2 (um)
Accuracy according GB/T16857.2-1997 equal ISO 10 360£º
(Volumetric length measuring error) E =2.9 +4L/1000um
(Volumetric Probing Error) R = 3.0um
D. RENISHAW Probe System