The APCS-2000 system can be adapted to virtually any tank configuration, large or small, simple or complex, easy or difficult. In a business climate that puts a premium on cost savings and environmentally friendly processes, manufacturing facilities that use the APCS-2000 system can give themselves a competitive advantage.
The system capability to drive a single sensor to monitor one cleaning head with four digital outputs to signal alarms andone digital input for optional external signal to signal start and stop of the cleaning cycle. It has an ethernet interface for connection to network and the system logs data of monitored cleaning cycles.
Thanks to its non-intrusive nature, APCS-2000 performs equally well in
- High- and low-temperature environments (up to 162 (C)/325 (F) )
- Pressurized CIP operations
- Caustic cleaning solutions

SPECIFICATIONS
System Power
Voltage: 24vdc +/- 15% @ .25 amp
Power consumption: 5.1 watts
Enclosure
Material: Glass Reinforced Polyester (RAL7001 grey)
IP Rating: 67
Certifications: ATEX EEx'e' BS EN 50019 (Zone 1 & 2) ATEX EEx'nA' BS EN 50021 (Zone2) NEMA 4X (CSA, UL & FM) (Class 1 division 2) GOST-R Ex'e' (Zone 1 & 2)
Dimensions (WxHxD): 6.3 x 6.3 x 3.54 (in), 160 x 160 x 90 (mm) Mounting (WxH): 5.5 x 7.1 (in), 140 x 180 (mm)
Operating Temperature
Electronics Unit: -4 to +140 (F), -20 to 60 (C)
Sensor: -65 to +250 (F), -54 to +121(C)
Alarm Outputs
Signalling Device: relay contacts