ZC-SG is a strain gauge signal converter. Measurements taken using the 6-wires or 4-wires technique are available through CANopen protocol. Sensitivity from 1 to 64mV/V, settable by DIP switch for integer values, via software for real/integer values. Stable weight indication via CANopen/digital output. Remote writing of the tare in volatile and/or non-volatile memory by digital input/CANopen.
Power Supply: - 10..40 Vdc, 19..28 Vac
Max consumption: - 1 W
Insulation: - 1,5 kVac (3-way)
Accuracy: - 0,01%
Resolution: - 24 bit
Load cell analog input: - Voltage supply 5 Vdc, min impedance 87 Ω (350 Ω, 4 load cells), 4 or 6 wire connection, sensitivity 1..64 mV
Digital input: - Tare calibration / span
Digital output: - Stable weight / limit switch
Response time: - 7 ms
Operating temperature: - -10..+65°C
Dimension WxHxD: - 35x100x112 mm