Humidity generator and calibration system
90% | Model 869
SETRA
Overview
The new Model 869 Expert System contains all of the same features as the new and more. The Expert System, when combined with Setra’s 269 pressure transducers and SRPM Room Pressure Monitors, has fully automated testing and hands-off calibration which reduces calibration times to 5 minutes or less. The 869 and 269 were specifically developed to be a full pressure transducer/ calibration solution for critical environments and HVAC applications. This pairing ensures automated communication, testing, and calibration between the two. This same logic was implemented in the development of the SRPM as well. Also, the calibrator can read analog output and communicate digitally.
Features
> Fully Automated, Hands-Off Calibration reduces calibration times by 2/3 or more
> No tube cutting or wire removal is required
> Easy-to-Use, Smart Communication Software provides transducer detection and automated calibration with Setra’s digital transducers and room pressure monitors
> Electropneumatic Interface Cable (EPIC) allows the 869 to simultaneously pressurize a 269 or SRPM under test and automatically transmit ID and calibration data between the two units
> Two EPIC Cable Lengths Offered: 6ft (standard) & 12ft (optional), providing easy access to units located in remote, difficult to access areas
The new Model 869 Expert System contains all of the same features as the new and more. The Expert System, when combined with Setra’s 269 pressure transducers and SRPM Room Pressure Monitors, has fully automated testing and hands-off calibration which reduces calibration times to 5 minutes or less. The 869 and 269 were specifically developed to be a full pressure transducer/ calibration solution for critical environments and HVAC applications. This pairing ensures automated communication, testing, and calibration between the two. This same logic was implemented in the development of the SRPM as well. Also, the calibrator can read analog output and communicate digitally.
Features
> Fully Automated, Hands-Off Calibration reduces calibration times by 2/3 or more
> No tube cutting or wire removal is required
> Easy-to-Use, Smart Communication Software provides transducer detection and automated calibration with Setra’s digital transducers and room pressure monitors
> Electropneumatic Interface Cable (EPIC) allows the 869 to simultaneously pressurize a 269 or SRPM under test and automatically transmit ID and calibration data between the two units
> Two EPIC Cable Lengths Offered: 6ft (standard) & 12ft (optional), providing easy access to units located in remote, difficult to access areas
-
zoom