Over-current protection relay SIPROTEC 7SJ series
for feederpanel-mountplug-in

over-current protection relay
over-current protection relay
over-current protection relay
over-current protection relay
over-current protection relay
over-current protection relay
over-current protection relay
over-current protection relay
over-current protection relay
over-current protection relay
over-current protection relay
over-current protection relay
Add to favorites
Compare this product
 

Characteristics

Measured/monitored value
over-current
Applications
for feeder
Mounting
panel-mount, plug-in
Other characteristics
digital, programmable, configurable, compact, high-voltage

Description

SIPROTEC 7SJ81, SIPROTEC 7SJ82, SIPROTEC 7SJ85 and SIPROTEC 7SJ86 The SIPROTEC 7SJ82/7SJ85 overcurrent protection has been designed specifically for protection of feeders and lines in medium-voltage and high-voltage systems. The SIPROTEC 7SJ86 overcurrent protection has specifically been designed as backup or emergency protection for the line protection devices. With its flexibility and the high-performance DIGSI 5 engineering tool, the SIPROTEC 5 devices offer future-oriented system solutions with high investment security and low operating costs. Features Main function: •Feeder and overcurrent protection Inputs and outputs: •4 current transformers, 11 binary inputs, 9 binary outputs •4 current transformers, 18 binary inputs, 14 binary outputs •4 current transformers, 4 voltage transformers, 11 binary inputs, 9 binary outputs •4 current transformers, 4 voltage transformers, 16 binary inputs, 11 binary outputs Hardware flexibility: •Different hardware quantity structures for binary inputs and outputs are available in the 1/3 base module. 1 plug-in module position, available with large or small display Housing width: •1/3 × 19 inches Functions DIGSI 5 permits all functions to be configured and combined as required. •Directional and non-directional overcurrent protection with additional functions •Detection of ground faults of any type in compensated or isolated electrical power systems using the following functions: 3I0>, V0>, fleeting contact, cos φ, sin φ, dir. detection of intermittent ground faults and admittance •Arc protection (note the resulting communication restrictions) •Overvoltage and undervoltage protection
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.