Safety-PLC
150 mA, 22 - 28 V | Integron 150 series
Smartscan
Safety control functions that the Integron can be used for include, E-Stop (immediate & delay output option), safety gate monitor (delay time option), run down time protection, press brake controllers, safety mat and edge monitoring, safety light guard monitor, robotic cell controllers and a great variety of customized safety control solutions. The inputs and outputs can be used singularly or can be paired to allow cross monitoring, the combination of which, allows them to be used for safety and operational control logic.
An Integron safety PLC comprises of the control box and two independent memory modules. The system can be programmed using industry standard ladder logic running on Windows based software.
Options for timers, speed monitors, relay outputs and counters are available with up to 120 rungs of logic (model dependent). The completed software is then 'blown' onto the memory modules via the programming unit and the memory modules are simply inserted into the PLC.