• Ex zone 0 and 20
• Stainless steel enclosure
• Flush or non-flush mounting
• Long life, no mechanical wear
• Suitable for the food processing industry
• Insensitive to soiling
• With LED
• M12 x 1 thread
• With pre-wired cable
• Attention: Please state required international approvals with your order!
• Appropriate intrinsical safe switch amplifiers see chapter / Ex IS Safe switch amplifiers >
• Applied standards - EN 60079-0, EN 60079-11, EN 60079-26
Enclosure - stainless steel 1.4305
Front cap - POM
Degree of protection - IP 66, IP 67, IP 68 (EN 60079-0 + IEC/EN 60529)
Connection - cable PUR blue
Cable diameter - 4.1 mm
Cable cross-section - 2 x 0.25 mm²
Switching system - Namur to EN 60947-5-6
Correction factors - Steel (Fe360) = 1; Stainless steel approx. 0.7; Brass approx. 0.5; Aluminium approx. 0.4; Copper approx. 0.4
Rated operating voltage range UB - 8.2 VDC
Current absorption - in presence of metal ≤ 1 mA; in absence of metal ≥ 3 mA
Switching frequency - 2000 Hz
Repeatability - ≤ 3 %
Protection circuit - Inductive interference protection, protection against polarity reversal, short-circuit and overload proof
Ambient temperature - –25 °C … +60 °C
Ex marking - II 1G Ex ia IIB/IIC T6 Ga,
II 1D Ex ia IIIC T85°C Da IP66/IP67/IP68
IECEx Ex ia IIB/IIC T6 Ga
Ex ia IIIC T85°C Da IP66/IP67/IP68
Approvals - IMQ 14 ATEX 001
IECEx IMQ 14.0001X