variable-area flow meter / for liquids / for gas / direct-reading
60M1 series TECFLUID

{{requestButtons}}

Characteristics

  • Technology:

    variable-area

  • Fluid:

    for liquids, for gas

  • Other characteristics:

    direct-reading, glass tube, in-line, top-mounted, stainless steel

  • Applications:

    for low flow rates, for water treatment, industrial

  • Process pressure:

    Max.: 15 bar (217.56 psi)

    Min.: 0 bar (0 psi)

  • Process temperature:

    Max.: 80 °C (176 °F)

    Min.: -20 °C (-4 °F)

  • Volumetric flow rate:

    Max.: 100 l/h (26.4 us gal/h)

    Min.: 0.1 l/h (0 us gal/h)

Description

Variable area flowmeters with glass tube for low flows.
Application areas

Suitable for all kind of industries for low flow measuring.
Technical specifications

Measuring ranges
0,1 l/h ... 100 l/h H2O
0,4 Nl/h ... 3500 Nl/h air

Accuracy:
±3% f.s.

Connections:
Threaded fittings R1/4” BSP or NPT

Materials:
Flow tubes: borosilicate glass, lenght 150 mm
Wetted parts: EN 1.4404 (AISI316L)