Programmable temperature controller
IP65 | TM9x52 series
Thermosystems
TM9x52 SERIES CONTROLLERS
POLIFUNCTIONAL CONTROLLER FOR METERING FUNCTIONS OF:
- temperature (RTD termoresistence)
- temperature (PTC / NTC)
- voltage (direct)
- resistence
- current (direct)
* - universal analog input selecting from TC J, K, L, N, T, R, S, B, Pt 100, mA, mV, V (PTC on request).
* - free setting parameters min/Vis_Lo - MAX/Vis_Hi
* - totally configurable through 4 push-buttons keyboard.
* - MAIN Set-Point with output relay or voltage for SSR or continuous (0/4-20mA, 0-5Vcc, 0-10Vcc, etc).
* - PID or on/off action selecting with all parameters setting.
* - not intrusive autotuning algorithm, selecting by Auto-Tuning or Self-Tuning.
* - Soft-Start/Ramp, Economy, ARW, Man/Auto functions, Modbus or Ascii communication protocol.
* - heating / cooling selecting.
* - °C / °F selection setting.
* - two independent ALARM Set-Points (I and II) each with relay output or voltage output for SSR.
* - 8 alarm functions helpful for each alarm channel.
* - multilevel numerical protection key-lock for data and setting security.
* - up to two independent digital inputs with selectable associated function.
* - double local Set-Point (Set1 - Set2).
* - remote Set-Point available, according to normalized signals.
* - high resolution continuous output associated to programming variable (retransmission).
* - HBM (heather break monitor) function.
* - programmer version (time / temperature relationship) due to 100 steps / 10 programs.
* - Set-Point and profile programmer version.
* - transducer's supply on board available.
* - digital serial output (RS232 or RS485) available.
POLIFUNCTIONAL CONTROLLER FOR METERING FUNCTIONS OF:
- temperature (RTD termoresistence)
- temperature (PTC / NTC)
- voltage (direct)
- resistence
- current (direct)
* - universal analog input selecting from TC J, K, L, N, T, R, S, B, Pt 100, mA, mV, V (PTC on request).
* - free setting parameters min/Vis_Lo - MAX/Vis_Hi
* - totally configurable through 4 push-buttons keyboard.
* - MAIN Set-Point with output relay or voltage for SSR or continuous (0/4-20mA, 0-5Vcc, 0-10Vcc, etc).
* - PID or on/off action selecting with all parameters setting.
* - not intrusive autotuning algorithm, selecting by Auto-Tuning or Self-Tuning.
* - Soft-Start/Ramp, Economy, ARW, Man/Auto functions, Modbus or Ascii communication protocol.
* - heating / cooling selecting.
* - °C / °F selection setting.
* - two independent ALARM Set-Points (I and II) each with relay output or voltage output for SSR.
* - 8 alarm functions helpful for each alarm channel.
* - multilevel numerical protection key-lock for data and setting security.
* - up to two independent digital inputs with selectable associated function.
* - double local Set-Point (Set1 - Set2).
* - remote Set-Point available, according to normalized signals.
* - high resolution continuous output associated to programming variable (retransmission).
* - HBM (heather break monitor) function.
* - programmer version (time / temperature relationship) due to 100 steps / 10 programs.
* - Set-Point and profile programmer version.
* - transducer's supply on board available.
* - digital serial output (RS232 or RS485) available.
-
zoom