WILKERSON
Group: Parker

Zero-loss condensate drain
232 psig, 150 °F WILKERSON

  • zero-loss condensate drain 232 psig, 150 °F WILKERSON
The WDV2 Electronic Demand Drain Valves, with zero air loss,
are suitable for all compressed air system applications from
aftercoolers to filters to receivers to refrigerated dryers. These
drain valves activate automatically and are both reliable and
economical.
Condensate (water, oil, and dirt) collect in the sump while the
diaphragm is held closed by system pressure. As soon as the
top sensor detects liquid, the solenoid energizes. The chamber
above the diaphragm deflates and the condensate is driven out
by system pressure. A timer is activated which allows a specific
amount of condensate out and closes before any air is lost. If
the unit gets clogged with a slug of condensate and scale, it will
pulse to push that slug out of the valve and allow it to continue
working properly. If the slug can not be removed after a set
period of time, an alarm light and contact will signal a problem.
• Zero Air Loss
• Automatically Self-Adjusting for Voltages
from 110 to 230V
• Sensor Device with No Moving Parts
• Sophisticated Electronic Controls
• Alarm with Remote Contacts
• Large Inlet Port to Eliminate Clogging
• Manual Push-to-Test Button
• Automatically Clears Slugs