Hand-held pressure calibrator
ECP3600
Xian Henry Automation
The self-contained portable pressure calibrator is best for field calibration, commissioning and maintenance of both instruments and their control loops, with capabilities of pressure and electric measurement, data storage, as well as facilities for 4 to 20 mA loop testing. It contains a built-in pressure generator with fine pressure control. The rugged industrial design is styled such that the pressure pump can be operated and test leads connected without compromising the visibility of the larger parameter display. The file storage function offers memory of up to 60 sets of instruments including information of tag numbers and calibration data.
Specifications︰ Technical Specifications
Pressure reading accuracy and ranges:
Reading -13 to 290 PSI (-90kPa to 2Mpa) with
following standard ranges.
Resolution 1 Pa and accuracy 0.075%FS:
0 to 10, 16, 20 kPa
and -16 to 0, -10 to 0, -10 to 10, -16 to 16 kPa
Resolution 1 Pa and accuracy 0.05%FS:
0 to 16, 20, 25, 40, 60 kPa
and -16 to 0, -10 to 0, -10 to 10, -16 to 16 kPa
Resolution 10 Pa and accuracy 0.05%FS:
0 to 100, 160, 200, 250, 400 kPa
and -90 to 0 kPa, 0 to 0.4, 0.6 MPa
Resolution 100 Pa and accuracy 0.05%FS:
0 to 1.0, 1.6, 2.0 MPa
Pressure generating by built-in pump:
Selectable range from -13 to 290 PSI (-90kPa to 2Mpa).
Electric accuracy and ranges:
Voltage: 0-200V, accuracy 0.05% FS.
Current: 0-30mA, accuracy 0.05% FS.
Output power for loop:
Output Power: 24V DC /-10%, max. current not exceeding 50mA.
Temperature:
Wider temperature from 5 to 40 deg. C.
Process connection:
1/4"NPT or 1/4"BSP
Sizes / Weight
300×150×115mm /2.5kg.
Specifications︰ Technical Specifications
Pressure reading accuracy and ranges:
Reading -13 to 290 PSI (-90kPa to 2Mpa) with
following standard ranges.
Resolution 1 Pa and accuracy 0.075%FS:
0 to 10, 16, 20 kPa
and -16 to 0, -10 to 0, -10 to 10, -16 to 16 kPa
Resolution 1 Pa and accuracy 0.05%FS:
0 to 16, 20, 25, 40, 60 kPa
and -16 to 0, -10 to 0, -10 to 10, -16 to 16 kPa
Resolution 10 Pa and accuracy 0.05%FS:
0 to 100, 160, 200, 250, 400 kPa
and -90 to 0 kPa, 0 to 0.4, 0.6 MPa
Resolution 100 Pa and accuracy 0.05%FS:
0 to 1.0, 1.6, 2.0 MPa
Pressure generating by built-in pump:
Selectable range from -13 to 290 PSI (-90kPa to 2Mpa).
Electric accuracy and ranges:
Voltage: 0-200V, accuracy 0.05% FS.
Current: 0-30mA, accuracy 0.05% FS.
Output power for loop:
Output Power: 24V DC /-10%, max. current not exceeding 50mA.
Temperature:
Wider temperature from 5 to 40 deg. C.
Process connection:
1/4"NPT or 1/4"BSP
Sizes / Weight
300×150×115mm /2.5kg.
-
zoom