LEONI outdoor cables
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Temperature: -40 °C - 70 °C
GYKTS is a kind of outdoor communication optical cable, which consists of a central metallic strength member, stranded loose tubes, a stainless steel tape armor and a PE outer sheath. Single-mode fibres ...
Yangtze Optical Fibre and Cable Joint Stock Limited Company
Temperature: -40 °C - 70 °C
GYFTA54 is a kind of outdoor communication optical cable, which consists of a non-metallic central strength member, stranded loose tubes, a laminated aluminum tape armor, a PE inner sheath, a stainless ...
Yangtze Optical Fibre and Cable Joint Stock Limited Company
Temperature: -40 °C - 70 °C
GYFTA53 is a kind of outdoor communication optical cable, which consists of a central metallic strength member, stranded loose tubes, a laminated aluminum tape armor, a PE inner sheath, a stainless steel ...
Yangtze Optical Fibre and Cable Joint Stock Limited Company
Temperature: -40 °C - 70 °C
ALTOS® Loose Tube, Gel-Free, All-Dielectric Cable with FastAccess® Technology 2 F, Single-mode (OS2) Environment - Outdoor Cable Type - Loose Tube Product Type - Dielectric Fiber ...
CORNING
Temperature: -5 °C - 70 °C
... layout and cable assembly Coaxial cable Triaxial cable Video cable Audio cable Multiconductor cable PTFE cable PUR ...
Temperature: -10 °C - 50 °C
Metal-free indoor and outdoor cable Strain relieved with aramid yarn For direct connector assembly Tight bending radii Low smoke, halogen-free and self-extinguishing Data cable ...
HUBER+SUHNER
Temperature: -35 °C - 80 °C
... fibre optic cable CFLG.LB Typical application areas . For heaviest duty applications with 5 - 7.5 x d . Maximum EMC protection, with high transmission qualities . Almost unlimited resistance to oil, also with bio-oils . ...
igus®
Nominal voltage: 450, 750 V
Temperature: -30 °C - 60 °C
Cross-section: 1 mm² - 500 mm²
heavy rubber connection cable oil resistant weather-resistant for medium mechanical stress Rubber connection cable, H07RN-F acc. to DIN VDE 0285-525-2-21 / DIN EN 50525-2-21; 07RN-F in alignment ...
HELUKABEL
Nominal voltage: 0 V - 750 V
Cables for systems in motion selected from experts Advantage 1 Secure choice of cables • Comprehension of our customers applications and needs is the foundation of our choice. We offer the safety ...
Nominal voltage: 500, 300 V
Temperature: -40 °C - 90 °C
Cross-section: 0.5 mm² - 25 mm²
... mm² CE Halogen-free, flexible cable, suitable for flexible and protected installation in the interior for door control or in protecting tubes for outdoor laying at the bogie, railway machines or as ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 300, 500 V
Temperature: -50 °C - 90 °C
Cross-section: 0.25 mm² - 35 mm²
Marking for SAB RailLine 560 65601105: SAB BRÖCKSKES · D-VIERSEN · SAB RailLine 560 5x0,75mm² C 6560-1105 CE For flexible outdoor installation, e.g. bogies, railway machines. Also for flexible application inside rolling ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 350, 1,500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.34 mm²
halogen-free Profibus-DP cable Marking for SABIX PB 630 56302341: SAB BRÖCKSKES · D-VIERSEN · SABIX PB 630 2x0,34 mm² CE The halogen-free Profibus-DP cable has bare copper strands according to DIN ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 3,000 V
Temperature: -40 °C - 80 °C
power, control and connecting cable in electrical facilities for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in dry, humid and wet ...
CAE GROUPE
Nominal voltage: 300, 500 V
Temperature: -30 °C - 70 °C
Cross-section: 1.75, 1, 0.75 mm²
... control and connecting cable in electrical facilities, for fixed laying and casually movement without tensile stress and without defined cable routing. Suitable for use in dry, humid and wet rooms (also ...
CAE GROUPE
Nominal voltage: 2,500 V
Temperature: -25 °C - 60 °C
The H07RN-F elastomer cables are flexible and resistant to oil, weather, UV and mechanical stresses. It enables the connection of apparatus in difficult industrial and outdoor environments. conform ...
CAE GROUPE
Temperature: -30 °C - 70 °C
... conception, obtained by using jelly and/or swellable elements, to stop the water propagation within the cable in case of cable accident. Outdoor cables are mainly installed ...
Temperature: -40 °C - 85 °C
... standard is a UV Resistant Polythylene jacketed cable designed for 20-year service outdoor use. The bending and handling characteristics are significantly better than any air-dielectric and corrugated ...
Distribution cables for blowing or pulling through ducts Dielectric and dry waterproof Duct cable widely adopted by major Telecom operators Combines compactness, lightness and robustness HDPE low-friction ...
High capacity cables up to 864 OF for ducts Excellent mechanical properties (tensile strength, crush resistance, bending radius) Dielectric and dry waterproof Well-suited for installation in narrow cabinets Easy ...
... available versions (fibre type, color coding). ACOPTIC® gathers ACOME’s optic cables solutions for telecom networks. MCD 1520 cables are the solution for micro-ducts based outdoor ...
2-fiber OM1 62.5/125μm multimode plenum (OFNP) indoor/outdoor all dielectric cable with tight buffered fibers.
... black • Cable Diameter ∅ 9 mm Shielded data cable with solid wire for structured cabling outdoors and under ground, according to ISO/IEC 11801 and ...
... Elevator cable for the use of steel cable core, can be used for long-range suspension use occasions. the use of new oil-resistant special jacket, can be -15 degrees low temperature is still soft, flame ...
Derulcable (Shanghai) Co., Ltd
... Elevator cable for the use of steel cable core, can be used for long-range suspension use occasions. the use of new oil-resistant special jacket, can be -15 degrees low temperature is still soft, flame ...
Derulcable (Shanghai) Co., Ltd
... Elevator cable for the use of steel cable core, can be used for long-range suspension use occasions. the use of new oil-resistant special jacket, can be -15 degrees low temperature is still soft, flame ...
Derulcable (Shanghai) Co., Ltd
Cross-section: 2.5 mm² - 120 mm²
Length: 0.2 m - 0.5 m
... fixed stationary indoor and outdoor installations, inside pipes, tubes and similar closed systems. It is designed to facilitate the connection of various photovoltaic system elements such as solar panels. H1Z2Z2-K ...
... such as solar panels. It is suitable for use in fixed stationary indoor and outdoor installations, inside pipes and macarons and similar closed systems. H1Z2Z2-K Twin cables; are suitable for UV rays, ...
Nominal voltage: 2,000, 1,000, 250 V
Temperature: -40 °C - 80 °C
... s. Applicable for interfaces CI 422 and 485. Li2YCY (TP)with reinforced black outer sheath (Yv) applicable for indoor and outdoor areas as well as for direct underground installation. For fixed installation in dry and ...
... Enables rapid fabrication of short custom cables Furcation cable option Available without the fiber or connectors Nylon pull-cord allows ruggedization of virtually any fiber Typical applications: Sensor ...
Cross-section: 16 mm² - 120 mm²
... Earth cables are made of rigid annealed electrolytic copper wires. Class 2 of standard IEC 60228. Wiring of concentric layers. So, the difference compared to copper cables is the fact that the ...
Nominal voltage: 300, 750, 450, 500 V
Temperature: -40 °C - 80 °C
... be used as control cables in tool machines, conveyor belts, production lines of machinery production,and air-conditioning systems. It is suitable for fixed applications or non-sustained shuttle bending movement, but ...
Zhaolong Interconnect
Temperature: -40 °C - 70 °C
... operational temperature for outside plant --40°C/70°C Compatible with a wide range of cables, 5-8mm OD cable with two 2.0mm to 3.0mm jacketed subunits\ Multi-purpose Outdoor For ...
T&S Communications
Nominal voltage: 600 V
Temperature: 60, 75, 90 °C
The XHHW-2 cable is extensively used in cable trench or cable conduit specified in the National Electric Code as the service conductor, feeder or branch line. Suitable for indoor and ...
... Especially when it comes to outdoor use in dry, humid or wet environments, it’s all the more important that the cable ensures secure handling of the tools. There is a huge variety of applications like ...
Fiber optic acoustic sensing cable, extra small, with stainless steel central metal loose tube, stainless steel strength members and PA outer sheath, good acoustic response, for up to 4 fibers. Description Compact ...
Brugg Kabel AG
Temperature: -40 °C - 70 °C
... constructions up to 864 fibres are possible. The stranded loose tube cables offer more options than any other cable construction family with regard to sheathing options. All cables feature ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining