Nominal voltage: 300 V - 750 V
Temperature: -15 °C - 70 °C
... single conductor for devices or measurements LIFY, power and control cable, PVC special single core, extra-finely stranded/extremely flexible measuring cable, protected for low voltage, ...
Temperature: -10 °C - 85 °C
... most advanced level in the world. It's applicable in all types including ribbon cable, loose tube stranded cable, slotted core cable, unitube cable ...
Yangtze Optical Fibre and Cable Joint Stock Limited Company
Temperature: -40 °C - 70 °C
... Allowing to cut micro ducts anywhere anytime for branch without influences on other cable, saving manholes, hand holes and cable joints • The cable can be used as the drop cable ...
Yangtze Optical Fibre and Cable Joint Stock Limited Company
Temperature: -40 °C - 70 °C
... anywhere anytime for branch without influences on other cables, saving manholes, hand holes and cable joints G is the weight of optical cable per km. • The cable ...
Yangtze Optical Fibre and Cable Joint Stock Limited Company
Temperature: -40 °C - 70 °C
... aerial Design and Test Criteria - ANSI/ICEA S-87-640 Corning recommends storing cable in a proper temperature environment prior to installation to allow the cable temperature to meet installation ...
CORNING
... well as effective cooling are just some of the characteristics of these cables. Secondary welding cables, also known as welding leads or welding power cables, are electrical cables ...
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm² - 185 mm²
... for selected torsion applications conditionally suitable for drag chains versatile use in many industries, particularly in machine and plant construction PVC control and connection cable in alignment ...
HELUKABEL
Nominal voltage: 500, 300 V
Temperature: -50 °C - 90 °C
Cross-section: 0.75 mm² - 16 mm²
... D-VIERSEN · SABIX® A 260 PUR 12 x 1,5 mm² CE SABIX® A 260 PUR is a cold resistant, flexible control cable with numbered cores. This oil resistant cable is weather resistant and is recommended for use ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 2,000, 300, 500 V
Temperature: -50 °C - 90 °C
Cross-section: 0.5 mm² - 240 mm²
... control cable with numbered cores for continuous movement Marking for S 200 07741215: SAB BRÖCKSKES · D-VIERSEN · S 200 12 x 1,5 mm² CE High flex cable with numbered cores for continuous movement ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 2,000, 600, 300, 500 V
Temperature: -50 °C - 90 °C
Cross-section: 0.5 mm² - 50 mm²
... PUR control cable with numbered cores Marking for S 980 P 77741807: SAB BRÖCKSKES · D-VIERSEN · 77741812 S 980 P 12 x 0,50 mm² 20 AWG/12c 77742012 UL AWM Style 21060 80°C 600V CSA AWM I/II A/B 80°C 600V FT1 FT2 CE Flexible ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 250 V
Temperature: -30 °C - 80 °C
... wiring of industrial field bus systems like PROFIBUS DP, F.I.P. With solid conductor AWG22/1 for hard wiring or with 7-wire stranded conductor for moving use without compulsory guide in the automation technology, transport ...
LÜTZE
... conveyor technology, heating and climate technology In dry, damp and wet rooms As a monitoring, measurement and control cable for industrial applications For flexible applications without compulsory guide PVC Flame-retardant, ...
LÜTZE
... conveyor technology, heating and climate technology In dry, damp and wet rooms As a monitoring, measurement and control cable for industrial applications For flexible applications without compulsory guide Properties PVC ...
LÜTZE
Cross-section: 0.5 mm² - 2,500 mm²
Length: 25 m - 1,000 m
Hard and soft copper cables for electrical applications. At Bronmetal we supply round copper wires for electrical applications. We supply copper conductor cable in line with international quality ...
Nominal voltage: 90 V
Temperature: -25 °C - 80 °C
... /Control Cables in AWG 22, shielded, zero halogen, flame retardant, with small outer jacket. High flexible stranded copper conductor, closed twisted pairs. NET Price per 1m - Cu included UL-approved ...
Metrofunk Kabel-Union
Nominal voltage: 1,000, 500 V
Temperature: -30 °C - 80 °C
Cross-section: 0.14, 0.2, 0.5, 0.08 mm²
Computer Cable with highly flexible stranded wire construction 0,08mm², outer shielding, 2 to 32 pairs, lightgray PVC-jacket
Metrofunk Kabel-Union
Nominal voltage: 150 V
Temperature: -30 °C - 80 °C
Cross-section: 0.14 mm²
Computer Cable with highly flexible stranded wire construction 0,14mm², outer shielding, 2 to 12 pairs, lightgray PVC-jacket
Metrofunk Kabel-Union
Nominal voltage: 300 V - 1,000 V
Temperature: -40 °C - 90 °C
Cross-section: 1.5 mm² - 240 mm²
Nominal voltage: 600 V
Temperature: 80 °C
Cross-section: 0.14 mm² - 95 mm²
Temperature: -30 °C - 70 °C
... installation cable U-DQ(ZN)BH • universal fiber optic cable for indoors/outdoors with central tube (up to 24 fibers) • bend insensitive fiber • UV-resistant, metal-free, longitudinally ...
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm² - 50 mm²
power, control and connecting cable in electrical facilities for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in dry, humid and wet ...
CAE GROUPE
Nominal voltage: 300 V - 500 V
Temperature: -40 °C - 80 °C
power, control and connecting cable in electrical facilities for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in dry, humid and wet ...
CAE GROUPE
Nominal voltage: 3,000 V
Temperature: -40 °C - 80 °C
power, control and connecting cable in electrical facilities for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in dry, humid and wet ...
CAE GROUPE
CUSTOM-MADE PRODUCTION: Formats and structures of cables made on request. Know-how: - Notching - Fitting - Stripping + crimping
Nominal voltage: 500 V
Temperature: -90 °C - 260 °C
... Capacitance: 105nF/km max Weight: 8g/m Attenuation: 108dB/100m Bend Radius: Fixed 10mm, Flexing 20mm RoHS Compliant – All Cables supplied by DJB Instruments UK Ltd and compliant with 2011/65/EU. The facts and ...
DJB Instruments UK Ltd
Nominal voltage: 30 V
Temperature: -50 °C - 80 °C
... jacket Conductor resistance: 200 MΩ/km Capacitance: 92pF/km max Impedance: 50±2Ω Weight: 29g/m RoHS Compliant – All Cables supplied by DJB Instruments UK Ltd and compliant with 2011/65/EU. The facts and figures ...
DJB Instruments UK Ltd
Nominal voltage: 30 V
Temperature: -60 °C - 80 °C
Inner conductor: 7 x 0.254mm tinned copper wire Insulation : 1.60mm diameter polyethylene Screen(s): 1 lay of 9/15μm Aluminium/polyester tape Tinned copper drain wire Sheath : PVC Overall diameter ...
DJB Instruments UK Ltd
Nominal voltage: 2, 3 kV
Temperature: -50 °C - 180 °C
Cross-section: 10 mm² - 300 mm²
... mm² out of single insulated silicone extruded cables 1,8/3 kV with solderless crimped contact areas and additional insulation crimp Technical data Electrical conductor: • Round stranded copper ...
Nominal voltage: 2, 3 kV
Temperature: -50 °C - 180 °C
Cross-section: 70 mm² - 300 mm²
... mm² out of single insulated silicone extruded cables 1,8/3 kV with solderless crimped contact areas and additional insulation crimp Technical data Electrical conductor: • Round stranded copper ...
Nominal voltage: 750, 500, 450, 300 V
Temperature: -12 °C - 80 °C
Cross-section: 0.75 mm² - 50 mm²
Carpel flat cable for moving equipment comes in a variety of N° conductors ranging from 6 to 24. The cores are identified according to CEI-UNEL 00722 tables and generally progressive numbering is used, with or without ...
Cross-section: 1.5, 1 mm²
The self-supporting electrical control cable engineered by By carpel is supported by dual side ropes that are inserted in the exterior sheath. This tool is specifically utilized on applications such as lifting sytems, ...
Temperature: -20 °C - 75 °C
Cross-section: 0.22 mm²
YM52451 24 AWG/0.22 mm² Non-category F/UTP Skew 5.1 ns/100 m Shielded version Stranded conductors
Belden Electronics GmbH Standort Neckartenzlingen
... material HDPE, the shape of the cable offers reduced contact surface to its low friction sheath. ACOPTIC® is the range of ACOME’s optical cables solutions for telecom networks. MCD1521-HD cables ...
Acome
Dielectric cables for blowing or pulling through ducts Entirely dielectric cable (earthing not required) Especially lightweight (a Tmax/weight factor much greater than 2), they can be deployed over ...
Acome
Distribution cables for blowing or pulling through ducts Dielectric and dry waterproof Duct cable widely adopted by major Telecom operators Combines compactness, lightness and robustness HDPE low-friction ...
Acome
Temperature: -40 °C - 90 °C
SOLAR cable means flexible single cables specialty designed for wiring solar plants. SOLAR cables arc extremely robust and resist high mechanical load and abrasion. High temperature ...
Temperature: -20 °C - 75 °C
Length: 10 m - 500 m
PRODUCT DESCRIPTION Stranded and shielded data cable for structured cabling according to ISO/IEC 11801 and EN 50173. The highly flexible data cable is suited for outdoor ...
Nominal voltage: 300 V
Temperature: -40 °C - 90 °C
Cross-section: 0.34 mm²
... sensor cable with a PUR outer jacket • Cable construction ○ 1. conductor pure stranded copper wire bare 7 x 0.245 mm ○ 2. insulation polypropylene ...
Nominal voltage: 300 V
Cross-section: 0.34 mm²
• Cable Construction • Conductor stranded CU wire blank 19 x 0,15 mm • Isolation Polypropylen • Outer Sheath PUR • Conductor Diamter Ø 0,76 mm • Wire ...
Temperature: 105 °C - 1,200 °C
... steel shields for applications where more strength is needed. Multiwire cable with pairs from 2 to 50, numbered with individual or group shields. High temperature extension wire with metallic sheath ...
Temperature: -10 °C - 105 °C
... bare copper drain wire Twisted cores & screened construction for reduced electrical noise Conductors PVC insulated and twisted together, aluminium Mylar® tape screen & drain wire, overall PVC sheath General ...
Labfacility Limited
Temperature: -60 °C - 350 °C
... Thermocouple Extension Leads with Mini Plug & Sockets Cable Description *Glassfibre insulated extension cable with stainless steel overbraiding *Thermocouple types K or J in lengths 2 or 5 metre *7/0.2mm ...
Labfacility Limited
Temperature: -75 °C - 260 °C
... mechanical strength and flexibility, resistant to oils, acids and other adverse fluids Thermocouple extension types for K Stranded 7/0.2mm conductors Available in 2 & 5 metre lengths Insulation rating -75°C to 260°C Colour ...
Labfacility Limited
Specification: 3x0.6 Conductor: Tinned copper Inner jacket: PE Outer jacket;PUR Breaking strength: 2000KG
Derulcable (Shanghai) Co., Ltd
Specification: 2x2x0.5 with air hose Conductor: Tinned copper Breaking strength: 500kg Jacket; TPU OD.; 11mm
Derulcable (Shanghai) Co., Ltd
Nominal voltage: 300 V
Derul Cable is able to design and manufacture Remotely Operated Vehicle (ROV) tethers. Power & signals are integrated into a cable structure, so ROV tethers can be used to transmit both electricity and ...
Derulcable (Shanghai) Co., Ltd
Cross-section: 2.5 mm² - 120 mm²
Length: 0.2 m - 0.5 m
... H1Z2Z2-K cables; are suitable for UV rays, ozone, bad weather conditions and are made of cross-linked material that does not contain halogen gases. They are resistant to fire and do not transmit flame. Electrolyticly ...
Ege Kablo Endustri Malz. San. ve Tic. A.S.
... systems. H1Z2Z2-K Twin cables; are suitable for UV rays, ozone, bad weather conditions and is made of cross-linked material that does not contain halogen gas. They are resistant to fire and do not transmit flame. Optimized ...
Ege Kablo Endustri Malz. San. ve Tic. A.S.
Temperature: 70 °C
Cross-section: 0.75 mm² - 1 mm²
... operating temperature This Product Has Been Certified By VDE. Certificate Number: 40037175 Single core, thin stranded copper conductor cables.
Ege Kablo Endustri Malz. San. ve Tic. A.S.
Nominal voltage: 800 V
Temperature: -30 °C - 70 °C
For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. Not approved for power and underground installation. DIN VDE 0815 ; directive 2014/35/EU RoHS 2011/65/EU EN ...
VOKA
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining