... FieldLink cable solutions, which, thanks to their robustness, can be deployed in a variety of industrial environments. The Ethernet bus cable range from Cat 5e up to cat 7 is available with twisted ...
Nominal voltage: 500, 300 V
Temperature: -40 °C - 70 °C
Cross-section: 0.22, 0.5, 1.5, 0.75, 1 mm²
In this chapter you will find multi-pair compensating and extension cables with PVC insulation for a temperature range up to 70°C.
SAB BROECKSKES GMBH & Co. KG
Temperature: 250 °C
Cross-section: 1, 0.22, 0.5 mm²
The PFA insulated extension cables for thermocouples are used for temperatures up to 250°C. They are available with galvanized as well as with a stainless steel wire armouring.
SAB BROECKSKES GMBH & Co. KG
Temperature: -40 °C - 70 °C
Cross-section: 0.75, 0.5, 1.5, 1, 0.22 mm²
In this chapter you will find compensating & thermocouple extension wires with PVC insulation. They are appropriate for temperatures up to + 70°C.
SAB BROECKSKES GMBH & Co. KG
Temperature: 250, 400 °C
Cross-section: 1, 0.22, 0.5 mm²
Thermocouple Cables for Thermocouples Type J, Type K, Type U, Type E, etc. The cables are halogen-free and especially appropriate for high temperatures up to +250°C or 400°C.
SAB BROECKSKES GMBH & Co. KG
Temperature: 250 °C
Cross-section: 0.18 mm²
This PFA insulated connection cable TGV with fibre-glass braiding and stainless steel wire armouring appropriate for temperatures up to 250°C.
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 2,200, 1,500 V
Temperature: -40 °C - 250 °C
Cross-section: 0.25 mm² - 6 mm²
• good EMC characteristics • flexible at low temperatures Conductor - bare copper strands, extra fine wires Core insulation - Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1 Colour code - black and red Stranding - ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm² - 50 mm²
power, control and connecting cable in electrical facilities for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in ...
CAE GROUPE
Nominal voltage: 300 V - 500 V
Temperature: -30 °C - 70 °C
HIFLEX-CH SH B2 shielded cables, type LiHCH, are used for analog and digital signal transmission in process and control equipment for applications such as: measuring, weighing, electronics, industrial automation. They ...
CAE GROUPE
Nominal voltage: 1,500 V
Temperature: -30 °C - 70 °C
HIFLEX-CH TP SH B2ca shielded multi-pair cables, type LiHCH-TP, are used for analog and digital signal transmission in control process equipment in measuring, control and adjustment technology, for data and signal transmission. The ...
CAE GROUPE
Nominal voltage: 500 V
Temperature: -15 °C - 80 °C
The CAEINSTRUM® instrumentation cables are used for the transmission of analogue measurement signals in the papermaking, chemical and petrochemical industries. • conform to RoHS • Hydrocarbon resistant acc to NF ...
CAE GROUPE
Nominal voltage: 300, 1,500 V
Temperature: -30 °C - 70 °C
The Profibus-DP protocol uses an RS485 high speed serial link and necessitates an impedance of 150 Ohm. The C-BUS/P cables meet this requirement, and furthermore their double shielding (aluminium tape + braid) ensure ...
CAE GROUPE
Nominal voltage: 300 V
Temperature: -30 °C - 70 °C
Length: 100, 500, 1,000 m
EIB CBUS cable is used to transmit information for Building Technical Management. conform to RoHS conductor material bare solid copper conductor conductor class Ø 0.80mm (AWG 20/1) core insulation PVC core identification ...
CAE GROUPE
Nominal voltage: 250, 1,500 V
Temperature: -30 °C - 70 °C
Cross-section: 0.22 mm²
The MC-22E cables enable the transport of electronic, signalling and communication signals in perturbated area thanks their dual shielding (braid + alu tape). • conform to RoHS conductor material stranded tinned ...
CAE GROUPE
Nominal voltage: 250, 1,500 V
Temperature: -30 °C - 70 °C
The MP-22E cables enable the transport of electronic, signaling and communication signals in pertubated area thanks their dual shielding (braid + alu tape) conform to RoHS conductor material stranded tinned copper conductor ...
CAE GROUPE
Nominal voltage: 250, 1,500 V
Temperature: -30 °C - 70 °C
Cross-section: 0.22 mm²
... codes industry stranding in twisted pairs Individual shielding aluminium / polyester tape + drain wire Overall shield aluminium / polyester tape + drain wire outer sheath PVC sheath colour grey
CAE GROUPE
Nominal voltage: 300, 1,500 V
Temperature: -20 °C - 80 °C
Low voltage computer cable; signal transmission RS 232 - RS 422 - RS 485 - Modbus • conform to RoHS conductor marerial stranded tinned copper conductor conductor class AWG 24: 7 x 0,20mm core insulation PE core ...
CAE GROUPE
Nominal voltage: 2,000, 600 V
Temperature: -30 °C - 70 °C
... DIN VDE 0815 As data transmission cable for transmission rates up to 10 kHz, mainly in power stations and other industrial plants. DIN VDE 0815 ; guideline 2014/35/EU RoHS 2011/65/EU EN 50575 ; EN 60332-1-2 ...
Temperature: -40 °C - 90 °C
... High flame resistance, meeting the requirements of IEC60332-1&IEC60332-3-25 Halogen-free, low smoke, low toxicity Acid and alkali resistance, ozone resistance Excellent ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining