Double-conversion UPS TLE
three-phaseVRLANi-Cd

double-conversion UPS
double-conversion UPS
Add to favorites
Compare this product
 

Characteristics

Type
double-conversion
Electrical characteristics
three-phase
Battery type
VRLA, Ni-Cd
Applications
data center
Other characteristics
automatic
Output power kVA

Min.: 160 kW
(217.5394 hp)

Max.: 1,000 kW
(1,359.6212 hp)

Input voltage

240 V, 277 V, 415 V, 480 V

Output voltage

240 V, 277 V, 415 V, 480 V

Description

The TLE Series UPS brings the latest power conversion technology to the marketplace, using a three-level inverter design and a multi-mode architecture that makes real time decisions between premium protection mode and premium efficiency mode. The TLE Series UPS was developed using ABB's Design for Six Sigma (DFSS) methodology to ensure that the product meets customer requirements for reliability and quality. ABB at Its Best Highly reliable and efficient tri-level conversion Automatic or manual multi-mode generation "Best of Both Worlds" Operating Efficiency Up to 99% premium efficiency mode (filtered eBoost) Up to 97% premium protection mode (double conversion) Electrical Environment Optimization Unity (1.0) Output Power Factor High (0.99) Input Power Factor Less than 5% Input Current Harmonic Distortion Physical Environment Optimization Small footprint Front access only design for maintenance "Cable saver" design to allow +/- 25% differential of cable lengths between UPS modules and the output parallel Energy Efficiency is Our Focus ABB's TLE Series UPS is one of the most energy-efficient double-conversion UPS in the industry and provides world-class energy efficiency across the operating load range. The TLE Series delivers efficiency up to 96.5% in double conversion mode and 99% in eBoost operating mode. This system efficiency substantially reduces operating and cooling costs thus providing a reduced cost of ownership and improved power usage effectiveness (PUE) compared to conventional UPS. ABB's UPS performance is optimized at 50-75% load operation, as this is the most common operating range.

Catalogs

No catalogs are available for this product.

See all of ABB UPS and power conditioning products‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

ACHEMA 2024
ACHEMA 2024

10-14 Jun 2024 Frankfurt am Main (Germany)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.