Visual grease volume monitoring
Measuring range 0.008–2 l/min
Low flow resistances
Any direction of flow
High compressive strength
The measuring mechanism, which consists of two high-precision gear wheels, is driven by the liquid flow according to the displacement principle.
The gears run almost contactless in the measuring chamber. Low-friction ball or plain bearings serve as bearing elements. Due to the measuring principle, no settling sections are necessary at the inlet and outlet.
This means that machines/plants can be designed more compactly. All moving parts are lubricated by the measuring medium.
The movement of the gearwheel is scanned contactlessly by two sensors in the cover as standard. When the measuring mechanism rotates by one tooth pitch, a signal is generated per sensor which corresponds to the so-called geometric tooth volume Vgz. The two-channel scanning enables a higher measured value resolution as well as a directional recognition of the flow.
Technical Data
Specific data
Flow measuring range
0.008–2 l/min
Measuring unit start-up
at 0.001 l/min
Linearised measurement accuracy
± 0.3 % of the measured value
(at viscosity: min. 20 mm²/s)
Repeatability
± 0.05 %
Resolution
40,000 pulses/l
Max. perm. pressure
200 bar
Operating fluid temperature
–15–120°C
Ambient temperature
–15–80°C
Max. foreign particle size
20 μm
Electrical data
Pulse volume
0.025 cm³/pulse
Line connection Pipe connection
G 1/8"
Electronic output
2 square-wave signals, 90° offset
Electrical connection
Plastic angle plug – terminal strip
Standard temperature version
Supply voltage
24 V DC ± 20 %
Materials
Material housing
Ductile cast iron EN-GJS 400