Variable-area flow meter SNS 552 series
thermal massfor liquidsstainless steel

variable-area flow meter
variable-area flow meter
variable-area flow meter
Add to favorites
Compare this product
 

Characteristics

Technology
variable-area, thermal mass
Fluid
for liquids
Material
stainless steel
Communication
4-20 mA, analog output, with pulse output
Applications
industrial, for water treatment, for the pharmaceutical industry, for marine applications
Other characteristics
compact, with display, bi-directional, with LCD display, programmable, two-sensor, digital
Volumetric flow rate

Max.: 5,000 l/min
(1,320.9 us gal/min)

Min.: 0.5 l/min
(0.1 us gal/min)

Process temperature

Max.: 80 °C
(176 °F)

Min.: 0 °C
(32 °F)

Process pressure

Max.: 60 bar
(870.23 psi)

Min.: -1 bar
(-14.5 psi)

60 bar
(870.23 psi)

Description

Compact - Precise - Multifunctional • Flow measurement of waterbased liquids • Temperature measurement • Pipe diameter adjustable • Teach-in functions • Manipulation detection Application The SNS 552 GAPL is a thermal flow sensor, for detection of the flow speed and the temperature of waterbased liquid medias in a pipeline. With the parameterizable inner diameter of the measuring pipe it calculates the current fluid consumption and displays it in the easy-to-read display in litres per minute or cubic metre per hour. For monitoring the flow condition the sensor has two independent switching outputs or an analog current output. Functions (selection) • Displayed measurand and unit of measurement selectable • Configurable outputs • 180° flipping of display • Status LEDs for units and switching outputs • TAG-ID • IO-Link Device V1.1 • Teach-in functions executable with IO-Link commands • Input for external control signal • User groups configurable The sensor is parametrized using the front buttons or the IO-Link interface. The 3-digit display shows the measurement values which can be sent as process data to an PLC via the IO-Link connection. Flow EGE offers thermodynamic flow controllers without moveable parts, which means they are robust and resistant to soiling. Controllers for fluids such as water, glycol mixtures or chemicals are as much part of the product range as sensors for gases such as air and carbon dioxide. Intrinsically safe sensors based on ATEX for explosive and hazardous Inline-Flow monitoring »

Catalogs

SNS 552
SNS 552
2 Pages

Exhibitions

Meet this supplier at the following exhibition(s):

All About Automation - Heilbronn 2024
All About Automation - Heilbronn 2024

15-16 May 2024 Heilbronn (Germany)