Device type - Receiver
Contains - 2x BT-NC sliding block
Application - Finger protection
Function package - Basic
Functions - Automatic start/restart
Transmission channel changeover
Type - 4, IEC/EN 61496
SIL - 3, IEC 61508
SILCL - 3, IEC/EN 62061
Performance Level (PL) - e, EN ISO 13849-1
PFHD - 7.73E-09 per hour
Mission time - 20 years, EN ISO 13849-1
Category - 4, EN ISO 13849
Resolution - 14 mm
Protective field height - 1,950 mm
Synchronization - Optical between transmitter and receiver
Protective circuit - Overvoltage protection
Short circuit protected
Supply voltage UB - 24 V, DC, -20 ... 20 %
Current consumption, max. - 150 mA
Fuse - 2 A semi time-lag
Number of safety-related switching outputs (OSSDs) - 2 Piece(s)
Type - Safety-related switching output OSSD
Switching voltage high, min. - 18 V
Switching voltage low, max. - 2.5 V
Switching voltage, typ. - 22.5 V
Voltage type - DC
Current load, max. - 380 mA
Load inductivity - 2,000 µH
Load capacity - 0.3 µF
Residual current, max. - 0.2 mA
Residual current, typ. - 0.002 mA
Voltage drop - 1.5 V
Switching principle - +24 V switching
Switching element - Transistor, PNP
Switching principle - +24 V switching
Switching element - Transistor, PNP
Response time - 42 ms
Restart delay time - 100 ms
Number of connections - 1 Piece(s)
Function - Machine interface
Type of connection - Connector
Thread size - M12
Type - Male
Material - Metal
No. of pins - 5 -pin
Permissible conductor cross section, typ. - 0.25 mm²
Length of connection cable, max. - 100 m
Permissible cable resistance to load, max. - 200 Ω