UV accelerated aging test chamber can simulate environmental conditions such as self-climate ultraviolet rays, rain, high temperature, high humidity, dew condensation, darkness, etc. By reproducing these conditions, it is merged into a cycle, and it automatically executes the number of cycles completed. In this process, the equipment can be used for automatic monitoring of blackboard temperature and water tank temperature; by configuring irradiance measurement and control device (optional), the irradiance can be measured and controlled, and the irradiance is stable at 0.76W/m2/340nm or specified setting. Fixed value, greatly extending the service life of lamps.
UV Accelerated Weathering Test Chamber is equipped with fluorescent UV lamp which can completely simulate the UV spectra of sunlight, exposes materials to alternating cycles of UV light and moisture at controlled, elevated temperatures. It simulates dew and rain with condensing humidity and/or water spray.
Water tank size is 50 Liter.
Sensors
Temperature sensor PT-100 A class
Resolution: ± 0.01 °C
Humidity sensor Dry and wet bulb sensors
Resolution: ± 1%RH
Irradiance Radiometer (UV-SI-260)
Chamber equipped with 8 pieces of UV lamp, which is air cooling.
Lamp length: 1160mm
UV lamp service life is 1600hours.
Over 1600 hours, must change new lamp.
Safety protection
Humidifier dry-combustion protection
Independent over-temperature protection,
Water shortage protection
Over-current protection
Over-current circuit breaker
Earth leakage protection and so on