float level sensor / for liquids / for water / compact
T039 TIDROM

{{requestButtons}}

Characteristics

  • Technology:

    float

  • Medium:

    for liquids, for water

  • Other characteristics:

    compact, with digital output, rugged

  • Level range:

    Max.: 40 m (131'02")

    Min.: 0 m (0'00")

  • Process temperature:

    Max.: 60 °C (140 °F)

    Min.: -30 °C (-22 °F)

Description

Measure principle: A conventional float system drives an absolute shaft encoder with digital output in Gray code(25 bits). A microprocessor based electronic module provides different outputs proportional to the hydrometric level.

Intelligent sensor: The transducer belongs to the intelligent sensor family and allows, among other functions, the correct control functioning, data pre-processing, electrical signal A/D conversion etc. These characteristics warrant excellent accuracy, long-term stability and high data reliability. It can be provided with an interface for data recording on removable memory card which can downloaded by a portable PC or withdrawn for next reading in the office.

Laboratory calibration: The sensor can be supplied with a SIAP+MICROS calibration certificate or with calibration certificates issues by external primary metrological services . Housing materials and International standards: A compact and robust die casting housing grants a IP 67 protection .
The transducer complies with CE EMC standards, it’s protected against over tensions and is fully compliant within the WMO (World Meteorological Organization) standards