Electronic display MA505
absolute, LCD dot matrix display, display accuracy 10 μm
Profile MA505:
Display accuracy max. 10 μm
Repeat accuracy max. ±0.01 mm
High-contrast LCD, 12-digit LCD dot matrix
Incremental measurement and calibration function
Direct reference/offset value input
Calibration input
Works with sensor MSA
Option: serial interface RS232/RS485
Option: TG01 bench housing
Feature - Technical data - Additional information
Housing design - built-in housing, plastic - switchboard cutout 92+0-8 x 45+0-6 IEC 61554
Electrical data - -
Feature - Technical data - Additional information
Operating voltage - 24 V DC ±20 % -
- 115 V AC ±10% -
- 230 V AC ±10% -
Current consumption - 70 mA - at 24 V DC
- 20 mA - at 115 V AC
- 10 mA - at 230 V AC
Display/display range - 12-digit, LCD dot matrix, backlit - -9999999 ... 9999999, arithmetic signs, units
Switching outputs - with or without - 2x30 V £100 mA
Interface - without, RS232, RS485 -
Type of connection - connector - 9-pole, (supply, switching output, interface/calibration input)
- mini-DIN - 8-pole, 1x Socket (MSA sensor)
System data - -
Feature - Technical data - Additional information
Resolution - 0.01, 0.1,1,10 mm - programmable angle display
- 0.001, 0.01, 0.1, 1 inch -
System accuracy - ±(0.05 + 0.03 x L) mm; L in m - atTu = 20=C
Repeat accuracy - ±0.01 mm - ±1 incrément
Travel speed - £5 nVs -
Ambient conditions
Feature___________________Technical data__________________Additional information__________
Ambient température_______0 ... 50 ;C
Storage température_______-20 ... 80 ;C___________________________________________________
Relative humidity - £95 % - condensation inadmissible
EMC - EN 61000-6-2 - interférence résistance / immission
EN 61000-6-4
emitted interférence / émission