Humidity and temperature probe for high-temperature applications DMP6
relativein-linedew-point

humidity and temperature probe for high-temperature applications
humidity and temperature probe for high-temperature applications
humidity and temperature probe for high-temperature applications
Add to favorites
Compare this product
 

Characteristics

Type
relative
Mounting
in-line
Technology
dew-point
Output
RS-485, Modbus RTU
Supply voltage
DC
Protection level
IP66
Other characteristics
high-precision
Applications
for industrial applications, for high-temperature applications, dust
Measuring range (temperature)

Min.: -25 °C
(-13 °F)

Max.: 100 °C
(212 °F)

Accuracy (temperature)

2 °C
(35.6 °F)

Working temperature

Min.: -40 °C
(-40 °F)

Max.: 80 °C
(176 °F)

Description

for In-Line Measurement in Very High Temperature Applications <350 °C Vaisala DRYCAP® Dew Point and Temperature Probe DMP6 is designed for in-line humidity measurement in industrial drying applications with very high temperatures and a wide dew point range. A high temperature tolerance is achieved using a passive cooling set that conducts heat away from the probe and reduces the temperature to within the optimal range for the sensor. DMP6 incorporates the Vaisala DRYCAP® sensor, which is accurate, reliable, and stable. The sensor is condensation-resistant and immune to particulate contamination, oil vapor, and most chemicals. Sensor warming minimizes the risk of condensation accumulating on the sensor. If the DRYCAP® sensor does get wet, it dries rapidly and recovers its swift response time. In low-humidity conditions the sensor will auto-calibrate to ensure accurate measurement. DMP6 is part of the Indigo family and is compatible with Indigo 200 transmitters. It can be used with the Vaisala Insight PC software for data visualization, easy probe configuration, and self-calibration. Features •In-line measurement for humidity at temperatures up to +350 °C (+662 °F) •Dew point measurement range -25 … +100 °C (-13 … +212 °F) Td •Dew point measurement accuracy up to ±2 °C (±3.6 °F) •Sensor purge provides superior chemical resistance •Withstands condensation, oils, dust and most chemicals •Modbus RTU over RS-485 for flexible connectivity •Compatible with Indigo series transmitters •Includes traceable three-point calibration certificate •Long (two-year) calibration interval for easy maintenance

Exhibitions

Meet this supplier at the following exhibition(s):

ACHEMA 2024
ACHEMA 2024

10-14 Jun 2024 Frankfurt am Main (Germany) Hall 11.1 - Stand C76

  • More information
    Intersolar 2024
    Intersolar 2024

    18-21 Jun 2024 Munich (Germany) Hall Vide - Stand B3.173

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.