Process temperature: -23 °C - 60 °C
Process pressure: 0 psi - 10 psi
Precision: 2 %
Gaining flow measurement inside a pipe can sometimes be tricky. The DFM 6.1 Doppler Flow Meter works as a non-contacting, clamp-on flow meter to offer ...
Pulsar Measurement
Process temperature: -20 °C - 80 °C
Process pressure: 0 psi - 10 psi
Precision: 0.25 %
... Area Velocity Flow Measurement method is the most common method of all flow measurements. The AVFM 6.1 Area Velocity Flow Meter uses a submersible ultrasonic sensor measuring ...
Pulsar Measurement
Volumetric flow rate: 0.1 ft³/s - 40 ft³/s
Process temperature: -40 °C - 150 °C
Precision: 1 %
... from one transducer to another. The time between transmitted and received signals is measured by the flow meter. Mount the TTFM 6.1 Transit-Time Flow Meter ultrasonic ...
Pulsar Measurement
Volumetric flow rate: 0.1 l/min - 2 l/min
Process temperature: -15 °C - 80 °C
Process pressure: 6, 10, 8 bar
... for this magnetic flow meter are diverse: Can be used in areas where flow sensors with moving parts (paddle wheel, turbine sensors) cannot be applied due to contaminated media Sensor ...
Mass Flow ONLINE BV
Volumetric flow rate: 0 l/min - 1 l/min
Process temperature: -20 °C - 90 °C
Process pressure: 16 bar
... for this magnetic flow meter are diverse: Can be used in areas where flow sensors with moving parts (paddle wheel, turbine sensors) cannot be applied due to contaminated media Sensor ...
Mass Flow ONLINE BV
Volumetric flow rate: 0.3 l/min - 6 l/min
Process temperature: -15 °C - 80 °C
Process pressure: 6, 10, 8 bar
... for this magnetic flow meter are diverse: Can be used in areas where flow sensors with moving parts (paddle wheel, turbine sensors) cannot be applied due to contaminated media Sensor ...
Mass Flow ONLINE BV
Process temperature: 40 °C - 230 °C
Precision: 1 %
Repeatibility: 0.25 %
SITRANS FS290 is a portable ultrasonic flowmeter system for monitoring volumetric flow in pipes. It contains the SITRANS FST090 battery-operated transmitter and SITRANS FSS220 clamp-on sensors. Install ...
Volumetric flow rate: 0.5 l/min - 75,000 l/min
Process temperature: -15 °C - 100 °C
Process pressure: 0 bar - 10 bar
The paddle wheel flowmeter for continuous flow measurement is especially designed for use in neutral, slightly aggressive, solid free liquids. The Bürkert designed fitting system ensures simple installation ...
BÜRKERT FLUID CONTROL SYSTEMS
Volumetric flow rate: 0 m³/s - 0.2 m³/s
Process temperature: 0 °C - 50 °C
Digital Flow Monitor • NPN/PNP Switch Function. • Can measure up to 12.000 l/min • Simple 3-Step Setting. • Compact & Lightweight. • Mounting: Bracket or Panel.
SMC
Volumetric flow rate: 0.1 l/min - 100 l/min
Process temperature: -10 °C - 70 °C
Process pressure: 10, 64, 100 bar
The High Performance MFM / MFC That Adapts To Your Process Intelligent Mass Flow Meters/Controllers EL-FLOW® Prestige, the latest generation thermal mass flow meters ...
Bronkhorst
Volumetric flow rate: 0.1 l/min - 1,670 l/min
Process temperature: -10 °C - 70 °C
Process pressure: 200, 400, 64, 100 bar
Proven Performance in Mass Flow Measurement & Control EL-FLOW® Select Series Mass Flow Meters/Controllers are thermal mass flow meters ...
Bronkhorst
Volumetric flow rate: 0.1 l/min - 50 l/min
Process temperature: -10 °C - 50 °C
Process pressure: 1,000, 1,500 psi
... as well as other high purity gas applications. The base blocks of the Mass Flow Meters and Controllers have 1/4" face seal male (VCR) connections. Metal Sealed Mass Flow Meter/Controller ...
Bronkhorst
Volumetric flow rate: 10 m³/h - 600 m³/h
Process temperature: -20 °C - 60 °C
... DN100 flow meter is an advanced electronic meter for natural gas flow measurement, which adopts ultrasonic technology to maintain long-term accuracy without degradation. With ...
Volumetric flow rate: 0.4 l/min - 25,400 l/min
Process temperature: 0 °C - 50 °C
Precision: 1.5 %
... DIN 50 and smaller sized flow meters have a powered (sourced) 4 to 20 mA analogue output which shares a common ground with the power supply. The output transmits a continuous current ...
OMEGA
Mass flow rate: 0 kg/h - 860,000 kg/h
Process temperature: -50 °C - 205 °C
... downstream piping requirements the compact Coriolis flowmeters can be installed in the tightest spaces, enabling applications not possible before. Up to five modular I/Os – Multivariable meter design – ...
ABB Measurement & Analytics
Mass flow rate: 0 kg/h - 250,000 kg/h
Process temperature: -50 °C - 205 °C
Process pressure: 0 bar - 60 bar
... Coriolis flowmeters can be installed in the tightest spaces, enabling applications not possible before. The FCH400 series delivers: Designed for hygienic applications – EHEDG certified Up to five modular I/Os – ...
ABB Measurement & Analytics
Mass flow rate: 0 kg/h - 860,000 kg/h
Process temperature: -50 °C - 205 °C
... series of compact system integration flowmeters feature low pressure drop, high flow capacity, high speed RS485 Modbus communication and 2 digital outputs. With no up or downstream piping ...
ABB Measurement & Analytics
Volumetric flow rate: 2 m³/h - 850 m³/h
Process temperature: 4 °C - 49 °C
Process pressure: 30 psi - 200 psi
Model 9090 Digital Flowmeter EXAIR's Digital Flowmeter, with data logging capability available, is the easy way to monitor compressed air consumption and waste! The digital display shows the exact amount of compressed ...
Volumetric flow rate: 2 m³/h - 850 m³/h
Process temperature: 20 °F - 120 °F
Process pressure: 0 psi - 250 psi
Model 9090-DAT Digital Flowmeter EXAIR's Digital Flowmeter, with Data Logger included, is the easy way to monitor compressed air consumption and waste! The digital display shows the exact amount of compressed air being ...
Volumetric flow rate: 6.6 m³/h - 8,496 m³/h
Process pressure: 200 psi
... available for most models. Available for measuring pressure and air flow in 2” thru 8” Schedule 40 Iron Pipe, in 50mm thru 101mm Aluminum Pipe and for 2” thru 4” Copper Pipe. These Digital Flowmeters ...
Volumetric flow rate: 60, 80, 520, 210, 320 l/min
Process temperature: 60 °C
Process pressure: 1 bar - 4 bar
Absolut wear and maintenance-free ultrasonic technology allows the flowmeter to measure with high precision and independently of the conductivity. It can also be extended with temperature and pressure sensors. The device ...
Mass flow rate: 0 kg/h - 450 kg/h
Process temperature: -50 °C - 205 °C
Process pressure: 430.9 bar
The compact Promass A is ideal for continuous process control in very demanding applications. Its unique self-drainable single-tube system enables accurate measurement of liquids and gases at lowest flow ...
Endress+Hauser AG
Process temperature: 0 °C - 80 °C
Process pressure: 3.5 bar - 7.5 bar
Repeatibility: 0.03 % - 0.3 %
... less for improved throughput High Accuracy Flow rate accuracy for process gas has been improved with an advanced three-dimensional adjustment Fast Response Response: < 0.8 second Accurate, stable flow ...
Process temperature: 0 °C - 50 °C
Process pressure: 35, 10 bar
Precision: 1.5 %
The KOBOLD MAS model mass flowmeter makes very précisé measurements of the mass flow rate of gases in différent measuring ranges from 0-10 Nml/min to 0-500 NI/min nitrogen. The opération of the meter ...
KOBOLD Messring GmbH
Process temperature: 5 °C - 50 °C
Process pressure: 0 bar - 10 bar
Precision: 0.35, 1 %
... Thermal Mass Flow Controllers & Meters One device. Multiple gases and flows. Maximum flexibility. Multiple gases in one device equals maximum process flexibility and productivity. ...
Brooks Instrument
Volumetric flow rate: 0 l/min - 300 l/min
Process temperature: 0 °C - 50 °C
Process pressure: 0 bar - 34.47 bar
... controllers and meters provides. Designed for semiconductor, MOCVD and other gas flow control applications, the GF100 series exceeds the semiconductor industry standard for reliability, ...
Brooks Instrument
Process temperature: 0 °C - 50 °C
Process pressure: 0 bar - 10.34 bar
Precision: 0.35, 1 %
... levels of purity—that’s the performance the GF100 series of metal sealed mass flow controllers and meters provides. Designed for semiconductor, MOCVD and other gas flow control ...
Brooks Instrument
Process temperature: 0 °C - 50 °C
Process pressure: 0 psi - 500 psi
Precision: 1, 2 %
New-Flow offers a large variety of products for measurement and control of temperature, pressure, flow, level, and valve. Service: for using in Non-Corrosive gas Output Signal: 0~5 VDC linear min. ...
Golden Mountain Enterprise
Process temperature: 0 °C - 50 °C
Process pressure: 0 psi - 500 psi
Precision: 2 %
New-Flow offers a large variety of products for measurement and control of temperature, pressure, flow, level, and valve. Service: for using in Non-Corrosive gas Output Signal: 0~5 VDC linear min. ...
Golden Mountain Enterprise
Process temperature: 0 °C - 50 °C
Process pressure: 500 psi
Precision: 2 %
Linear Output Thermal Technology For Using In Non Corrosive Gas For Flow Rates up to 100 SLM Power Supply Included The NEW-FLOW ETSF Series-Explosion proof type thermal mass flow ...
Golden Mountain Enterprise
Volumetric flow rate: 5 l/min - 10 l/min
Process temperature: 0 °C - 60 °C
Process pressure: 6 bar - 20 bar
FLOW MASTER is a flow volumetric device which allows the constant monitoring of the lubrication delivering. As the measurements are volumetric, they don’t depend on temperature or viscosity but they ...
Process temperature: -20 °C - 40 °C
Process pressure: 10 bar - 400 bar
The Flow metering device is designed to volumetrically monitor small flow rates on low pressure lubrication systems. Its operation is based on the progressive system operating concept. The displacement ...
Volumetric flow rate: 5 l/min - 250 l/min
Process temperature: -20 °C - 90 °C
Process pressure: 16 bar
... calibration certificate The sensors of the induQ® VMI series allow a flow- / volumetric flow measurement of electrically conductive liquids without moving parts. These are the ideal flow ...
SIKA
Process temperature: -20 °C - 80 °C
Process pressure: 100 bar
sensor flow, Water, Calorimetric, Ø40mm 73long, G1/4 inch, 24V DC, PNP NO (NO), Plug-in connection M12 4pin, V4A, Pressure resistance 100bar, Manual adjustment including 1x Screwdriver Flow ...
Process pressure: 0.6 mbar - 4 mbar
Precision: 0.2 %
... Robust housing Excellent flow mesurement accuracy, can measure duplex flow, electromagnetic debimeter with 4-20mA and other outputs General Features Excellent small flow mesurement ...
Volumetric flow rate: 1.6 m³/h - 3,125 m³/h
Process temperature: -40 °C - 70 °C
Process pressure: 1 bar - 10 bar
... reasonably priced, most accurate flow meter tailored for your applications. A flowmeter with base functionality, short delivery and a simple and clearly understandable documentation. EPD ...
Process temperature: -15 °C - 85 °C
Integral Ultrasonic Flow meter for liquid measurement The S-flow flow meter contributes to energy savings and production process solutions. Reduces ...
Precision: 0.25, 0.4 %
Repeatibility: 0.5 %
... various sensor parameters, anticipating possible problems. The battery converter with integrated modem MV255, flow meters, energy meters, contact our specialists.
ISOIL Industria Spa
Process temperature: -30 °C - 130 °C
Precision: 1, 3, 0.5 %
Repeatibility: 0.15 %
... the Modbus. Description The portable clamp-on flow meter IFX-P210, flow meters, energy meters, ultrasonic flowmeters, and industrial automation systems ...
ISOIL Industria Spa
Process pressure: 16 bar
Precision: 2 %
The insertion flowmeter CS3795 ISOMAG in compact version without indicator, which integrates sensor and converter in the same body. The compact insertion flow meter without indicator ...
ISOIL Industria Spa
The SeFlow 400 is Sewerin’s single channel portable flowmeter for applications in the municipal water and wastewater sector offering long term stable and precise bidirectional flow measurements in remote ...
Process temperature: -20 °C - 800 °C
Measurement of the volume flow, especially in dusty applications. Easy installation on existing ducts, no Venturi or similar conversions are required. Can be used in environments with low dust loads or in harsh conditions ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining