HBM acquisition amplifiers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Measuring Amplifier, latest Generation V7 with Data Logger Function for D7 Transducers (Passive Sensors with mV/V Output Signal and D7 Plug), Sensor-Specific Parameters in the Digital Measurement Plug, Fast Measurements ...
Lorenz Messtechnik
Voltage: 105 V - 240 V
... as: The modular amplifier cards are designed to operate with every probe diameter configuration and several sensitivity ranges by simple recalibration. For applications that require use of multiple sensors, the ...
Voltage: 0 V - 10 V
The 4100 series amplifiers are repairable including the plug in pre-amplifiers - please contact the factory for options An upgrade to the 4100 series is the Capteura® 200 Series The 4000 Series ...
Frequency: 0 Hz - 20,000,000 Hz
The EL-LNA-2 is a 2-channel amplifier manufactured by Elsys. It is designed for any 3rd party data acquisition system. The amplifier offers an option between two gain stages of x10 ...
Voltage: 10, -10 V
Current: 200 mA
Frequency: 10 Hz - 50,000 Hz
• Integrated, optional 24-bit data acquisition with up to 200 kSps per channel • Optional virtual channel feature (together with DAQ and PTP sync.) • Compatible with differential sensors like Kistler ...
Voltage: 24 V - 230 V
... top-hat rail (DIN EN 50022-35) The isolation amplifier DTVU20 is mainly used for the conversion of standard signals. Fields of application are complex measuring and control circuits, process data acquisition ...
Voltage: 30 V
Current: 10 A
Frequency: 2 Hz - 20,000 Hz
Easy-to-use class-D power amplifier designed to work with electrodynamic shakers in the lab or in production. The nominal output power of the amplifier is 200 VA. Digital amplifier ...
RULA Technologies
Voltage: 44 V
Current: 11.5 A
Frequency: 20,000 Hz
Easy-to-use class-D power amplifier designed to work with electro-dynamic shakers in the lab or in production. The nominal output power of the amplifier is 500 VA. The amplifier is ...
RULA Technologies
Voltage: 78 V
Current: 18.5 A
Frequency: 20,000 Hz
Easy-to-use class-D power amplifier designed to work with electro-dynamic shakers in the lab or in production. The nominal output power of the amplifier is 1200 VA. The amplifier is ...
RULA Technologies
Power: 70 W
Frequency: 0 MHz - 4 MHz
... of this Spectra-Physics’ imaging source for 3P, very high acquisition rates are possible. • High average and peak power for 3P imaging up to 4.3 MHz repetition rate • Fast image acquisition rate for ...
Voltage: 4.5 V - 36 V
Current: 4.4 mA
Frequency: 4 MHz
... 125°C Specified Temperature Range Small 12-Lead 4mm × 4mm DFN (LFCSP) Package The LTC6373 is a precision instrumentation amplifier with fully differential outputs which includes a closely matched internal resistor network ...
Frequency: 50 Hz - 5,000 Hz
... additional acquisition hardware required About Digital Accumeasure Gen 3 Our new capacitance amplifier converts the probe capacitance directly to target gap (distance). This direct conversion approach ...
Voltage: 0 V - 10 V
Current: 4 mA - 20 mA
Our intelligent strain gauge bridge amplifier is a compact, stackable microprocessor based unit specifically designed to control and monitor process applications. Flexible connection to most load cells, pressure or strain ...
Voltage: 10 V
Frequency: 50 kHz
... decoupled - reusable for other measuring tasks CONDITIONED TO VOLTAGE. The measuring amplifier MA-U adjusts voltage signals to the 5V input of a PC data acquisition system. To emphasize is the extremely ...
BMC Messsysteme GmbH
Voltage: 5 V
Frequency: 50 Hz
Single channel, handheld signal conditioner for GaAs-based fiber optic temperature sensors About the Pico M Fiber Optic Amplifiers Full featured, plug and play, 50 Hz sampling rate in a robust packaging. The Pico ...
Althen sensors
Voltage: 500 V
... needing galvanic isolated amplifiers. All types of measuring with universal acquisition card: temperature, distortion, pressure, force, acceleration, displacement… DESCRIPTION E325 is a very flexible ...
Frequency: 40 kHz
... comes in a rugged enclosure and features round plugs is the right solution for you. The MX460B-R is suited for precise acquisition of digital signals in off-road vehicle testing or test bench applications. In addition, ...
Voltage: 1,000 mV
Current: 0.02 mA - 0.2 mA
Frequency: 0 kHz - 1,000 kHz
... Instrument is proud to introduce the latest cutting-edge tool for electrophysiology research, the dPatch® Digital Patch Clamp Amplifier. Using high-speed digital processing, matched with high-resolution data converters ...
Voltage: 1,000 mV
... IPA® family of Integrated Patch Amplifiers, which enables efficient, low-noise whole-cell recordings. The IPA system, available with one (IPA) or two recording channels (Double IPA), combines state-of-the-art amplifier ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining