Metrofunk copper cables

1 company | 73 products
{{#pushedProductsPlacement4.length}} {{#each pushedProductsPlacement4}}
{{product.productLabel}}
{{#if product.activeRequestButton}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement4.length}}
{{#pushedProductsPlacement5.length}} {{#each pushedProductsPlacement5}}
{{product.productLabel}}
{{#if product.activeRequestButton}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement5.length}}
data electrical cable
data electrical cable
UL-11Y series

Temperature: -25 °C - 80 °C
Nominal voltage: 90 V
Cross-section: 0.25, 0.34 mm²

... ensure a round cable structure, the pairs are twisted with cotton filler and the resulting cable bundle is then wrapped with transparent polyester foil. Braided full shielding: Under the PUR jacket ...

See the other products
Metrofunk Kabel-Union
data electrical cable
data electrical cable
LifYCY series

Temperature: -10 °C - 80 °C
Nominal voltage: 100 V - 500 V
Cross-section: 0.08, 0.5, 0.2, 0.14 mm²

... Preferred application Pulse and data transfer connection cables for electronic systems, control and regulation systems, measurement and signalling systems and as interconnection cables for paging ...

See the other products
Metrofunk Kabel-Union
data electrical cable
data electrical cable
LifY(CB)Y-CY

Temperature: -10 °C - 80 °C
Nominal voltage: 100 V
Cross-section: 0.08 mm²

... data Highly flexible data transfer cables Pairs tightly twisted, each pair shielded and insulated, full shielding. Preferred application Interference-free transfer of data at low currents; pulse connection cables ...

See the other products
Metrofunk Kabel-Union
data electrical cable
data electrical cable
LiYCY-CY

Temperature: -10 °C - 80 °C
Nominal voltage: 250 V
Cross-section: 0.25 mm²

... to form the cable. Full shielding: The twisted core pairs are additionally shielded by an outer braid of tinned copper wires with a visual coverage of approx. 85%. Outer jacket: PVC, colour light ...

See the other products
Metrofunk Kabel-Union
data electrical cable
data electrical cable
LiYCY

Temperature: -10 °C - 80 °C
Nominal voltage: 500 V
Cross-section: 0.75 mm²

... Twisted-pair control signal cable with full shielding and light blue jacket (RAL 5015) Special features The full shielding prevents interference and external influences Construction data Conductors of tinned, ...

See the other products
Metrofunk Kabel-Union
LIYY type electrical cable
LIYY type electrical cable
LiYY

Temperature: -10 °C - 80 °C
Nominal voltage: 250 V
Cross-section: 0.14 mm²

... twisted pairs Preferred application Connection cables for electronic systems (e.g. computers, printers, etc.), control and regulation systems, measurement and signalling systems and as interconnection cables ...

See the other products
Metrofunk Kabel-Union
connection electrical cable
connection electrical cable
LIY-LIY(CB)-Y

Temperature: -10 °C - 80 °C
Nominal voltage: 250 V
Cross-section: 0.14 mm²

... DIN 47414, twisted pairs The 1st core pair in each cable has a braided shield. Preferred application Connection cables for electronic systems, control and regulation systems, interconnection cables ...

See the other products
Metrofunk Kabel-Union
data electrical cable
data electrical cable
LiYCY

Temperature: -10 °C - 80 °C
Nominal voltage: 250 V
Cross-section: 0.14 mm²

... twisted pairs Preferred application Connection cables for electronic systems (e.g. computers, printers, etc.), control and regulation systems, measurement and signalling systems and as interconnection cables ...

See the other products
Metrofunk Kabel-Union
power cable
power cable
JE-LiYCY

Temperature: -5 °C - 70 °C
Nominal voltage: 600 V
Cross-section: 0.5 mm²

... (2 x 2 to 12 x 2) x 0.50 mm2 Technical data Flexible installation cable for power station systems and industrial electronic systems Preferred application Connection cables for control and regulation ...

See the other products
Metrofunk Kabel-Union
data electrical cable
data electrical cable
J-Y(ST)Y

Temperature: -5 °C - 70 °C
Nominal voltage: 220 V
Cross-section: 0.28 mm²

... embedded in plastics and the additional copper drain wire provide 100% shielding against external electrical interference. The large production quantities resulting from the many possible applications ...

See the other products
Metrofunk Kabel-Union