Pico plug-in transformers
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Output power kVA: 0.03 kVA - 2.5 kVA
Primary voltage: 230 V - 400 V
Secondary voltage: 24 V
Secondary earthing by plug-in jumpers (depending on model) Signalling LED Operating temperature +60°C Series/parallel wiring of secondary windings by plug-in jumpers (depending on model) Fixing ...
Primary voltage: 26, 115 V
Frequency: 400 Hz
Manufactured to MIL-PRF-27, Grade 5, Class S. 90º C Ambient. Regulation is 24% (T Units Have Regulation of 17%) Secondary Voltage Adjusted to Nominal Value at Half Load. Smallest Possible Size. Printed Circuit Thru Hole Construction. Secondary ...
Electric power: 200 W - 400 W
Output power kVA: 0.2 kVA - 0.4 kVA
Primary voltage: 10 V - 24 V
General Characteristics • Dimensions according to CEI-UNEL 21009 std • Manufactured and tested acc. to IEC 61869-1/2 • Rated Insulation level up to 36 kV • Frequency 50 or 60 Hz • Rated primary current (Ipr) Single primary ...
Electric power: 200 W - 400 W
Output power kVA: 0.4, 0.2 kVA
Primary voltage: 10 kV - 24 kV
... phase VT to be connected to the MV line through plug-in bushings, type A interface, protected by two MV fuses, all contained in an ≥ IP 55 metal case; the connecNon to the motor is by means of a ≥IP55 plug. ...
Output power kVA: 0.005, 0.0015, 0.0038, 0.0025 kVA
Primary voltage: 1.2 kV
Secondary voltage: 720 V
• This Winding current transformer is mostly used for new installations, as the circuit must be interrupted here. • Most cost-effective and most common variant • Currently the most compact design on the market, thus ...
Output power kVA: 0.001 kVA - 0.0075 kVA
Primary voltage: 1.2 kV
Secondary voltage: 720 V
• This clip-on current transformer is mostly used for new installations, as the circuit must be interrupted here. • Most cost-effective and most common variant • Simply plug the transformer ...
Output power kVA: 0.001, 0.0015, 0.002, 0.0025, 0.005 kVA
Primary voltage: 1.2 kV
Secondary voltage: 720 V
• This calibrated current transformer is suitable for billing purposes • The design is approved by the Physikalisch Technische Bundesanstalt (PTB) Braunschweig • This transformer is mostly used for ...
... connected to the following toroidal current transformers. They must be crossed by the cables of the line to be controlled; insert the phases and neutral if present. The earth cable must NOT cross the current transformer. NOTE: ...
Secondary voltage: 0.3 V
Primary current: 0 A - 1,000 A
Secondary current: 5 A
XH-SCT-T70 Split Core Curren Transformer CTs Specifications: 1.Rated current:0-1000A 2.Rated output:mA or mV(0.333V) or A(1A,5A) 2.Insulation Voltage:3KV 3.Rated Frequency:50HZ/60HZ 4.Operating Temperature:-15℃to ...
Secondary voltage: 0.3 V
Primary current: 0 A - 800 A
Secondary current: 5 A
FSCT40 Split Core Current Transformer CTs Specifications Window Size:40mm Input:0-800A Output:5A,1A,mA,mV,V Burden:2.5VA/5VA Wire Lead:2*2.5mm² sheathed wire Standard: GB/T 20840. 1 and . 2; Pressure Voltage: ...
Secondary voltage: 0.3 V
Primary current: 0 A - 5,000 A
Secondary current: 5 A
The JIANGYIN SPARK Busbar KN Series of split core current transformer are designed for fast and easy installation.The split core design permits non-contact current measurements through magnetic field induction without ...
Primary current: 5 A - 2,500 A
Moulded case current transformer for billing purposes Main features Moulded case current transformer for billing purposes The applicable regulations for kWh measurement devices can be fulfi lled with ...
Cable split core for retrofitting existing systems Compact, splitting current transformers for retrofi tting Ideal for retrofitting as the primary current circuit need not be disconnected Ideally suited for ...
Electric power: 0.05, 0.1, 0.2 kVA
Primary voltage: 230, 120 V
Secondary voltage: 110, 230 V
Isolating transformers, according to the VDE and EN instructions. Type TTGN 2 is a plug-in unit which is plugged directly into the 230 V main socket. Types TTGN 20 mounted in a steel-case with ...
HSGM
Electric power: 0.16 W - 2.5 W
Primary voltage: 230 V
Secondary voltage: 230 V
General Data Rated input voltage 230 Vac Rated output voltage 230 Vac Rated power 160 ‑ 2500 VA Insulation class A Maximum ambient temperature 40 °C Degree of protection IP 67 Advantages Safe galvanic isolation Integrated short circuit ...
Block Transformatoren-Elektronik
Primary voltage: 720 V
Primary current: 100 A - 1,500 A
Frequency: 50, 60 Hz
... multi-range current transformer with 5 VA nominal burden and accuracy class 0,5 S is qualified for electronic metering. Due to the extendet measuring range, the whole range from 100 to 1500 A can be covered by 3 courant ...
... ZGS11 combined transformer consists of high-voltage and low-voltage chambers and transformer tank in the operation chambers. 2.H.V.incoming lines in 10KV cross-linked cables are connected to load switch ...
Primary voltage: 6.4 V - 11 V
Secondary voltage: 3.2 V - 5.5 V
The AS0028100 and AS0028101 are not really part of the Copper IRIG-B Distribution System but they are derived from the Model 10882 IRIG-B Distribution Tap. They work with modulated IRIG-B and isolates the source from the end device. The ...
Electric power: 0.5, 0.75, 1 kVA
Input: Schuko-Konturenstecker Output: 1x Schuko ohne Erdbügel Power: 500VA Voltage: 230/230V Weight: 5,5 KG Model Code: 2112
Electric power: 36 W
Primary current: 0 A - 600 A
Frequency: 50, 60 Hz
CY-EITDZ1-36W type current and voltage combined transformer using plug-in type, independent pillar installation design. It suitable for outdoor pole-mounted installation. And can provide three-phase voltage ...
Electric power: 0.1 kVA - 3.7 kVA
Primary voltage: 230 V
Secondary voltage: 230 V
Isolating transformers according to EN 61558-2-4, double insulated, in a solid portable metal enclosure (metal-clad transformer of protection class II). Conditionally short-cicuit-proff due to a built-in ...
Our power transformers are including lead wore, pin, toroidal and 3 phase series.
Output power kVA: 0.25 kVA
Primary current: 100 A
Secondary current: 5 A
WAGO's plug-in current transformers (855 Series) are inductive, single-conductor current transformers. Due to the measurement principle used, these current transformers ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining