Hydrostatic pressure cell for liquids in the range of 0.1 to 100 MPa.
This new product is used for studying samples in the pressure range between 1 and 1000 bar (0.1 and 100 Mpa). Measuring phase transitions of lipids or a sample's structural changes under differing pressures are only a few examples where the HP-Cell will bring interesting results.
|
|
The TE250 Laboratory Ring Pulverizer is the most rugged system of its type. It is used to pulverize a variety of samples to analytical fineness, suitable for analysis by XRF, XRD or optical emission.
A full 1HP motor with direct drive counter weight is used to provide capability for continuous grinding, 24 hours a day, 7 days a week. A simple "scissors" type clamping mechanism is used for reliable, safe operation, grind after grind. Many container types are available in sizes ranging from 10cc sample size up to 250cc sample size.
|
|
Powder X-ray diffractometer
EQUINOX 2000 X-ray Diffraction Systems employs a unique patented curved detector that replaces the conventional scanning goniometers used on other commercial instruments.
This unique detector is able to measure all diffraction peaks simultaneously. It eliminates the need for mechanical scanning devices and does no require complex scanning goniometers used in most other X-ray diffraction instruments.
|
|
|
|
|
|
The New D8 ADVANCE - the 1st truly all-purpose Diffraction Solution for X-ray Powder Diffraction
The new D8 ADVANCEThe innovative design of the new D8 ADVANCE plausibly combines operating safety, ease of use, and user safety. Well-matched hardware, electronics, and software ensure an easy adaptation to any application in the field of X-ray powder diffraction. The intelligent beam path components of the new D8 ADVANCE provide true plug'n play functionality requiring minimum or even no user intervention. Featuring automatic and tool-free switching of the diffraction geometry without the need for complex adjustments the new D8 ADVANCE broadens the analytical capabilities for a wide community of X-ray diffraction users. Together with the 'Best-Data-Guarantee' which refers to the 'Alignment Guarantee' and 'Detector Guarantee' it just means: operating safety assured.
The new D8 ADVANCE comes with the new software DIFFAC.SUITE. The plug'n play functionality is consistently implemented: any component mounted to the instrument registers itself with its relevant parameters. The DIFFRAC.SUITE offers intuitive operation and the graphical user interface can be customized to match the operator's requirements, and last but not least features the leading algorithms of its predecessor DIFFRACplus - ease of use assured.
Finally, the new D8 ADVANCE complies with all the recent X-ray, machine, and electric safety directives of the EC, which is certified by various independent institutions. Thus running the new D8 ADVANCE in universities, research institutes, R&D laboratories, quality control environments etc. means comprehensive user safety and minimum effort with the local authorities supplying the permission to operate the instrument.
|
|
|
|
|
|
SAXSess mc² – the modular tool for nanostructure analysis
The SAXSess mc² is a new system for structure characterization on the nanometer scale. Its modular architecture allows users to select the optimal setup for their needs. The SAXSess mc² is the complete solution for the characterization of nanostructures in various materials ranging from proteins, nutrients and active pharmaceuticals to polymers, nanoparticles and catalysts.
A small genius
* Compact design ensures high intensity and ease of use.
* Short measurement times increase sample throughput.
* Clever collimation concept results in unmatched measurement range beyond 200 nm.
Modularity for any needs
* Different powerful X-ray sources and advanced detectors available.
* TrueSWAXS - Simultaneous small- and wide-angle measurements up to 40° scattering angle.
* SmartSAXS - Double beamline option for ultimate experimental possibilities.
* All system devices are integrated in one compact platform with a small footprint.
Unmatched sample handling options
* Versatile sample holders for any sample type (e.g. proteins, polymers,...).
* Precise temperature control from -150 °C to 300 °C.
* High throughput screening of liquids and solids easily possible.
* Multi-directional positioning for sample mapping.
Powerful control and data analysis software
* Full system automation for time- and temperature-dependent experiments.
* Fast and simple data processing using customizable templates.
* Versatile data interpretation and model calculation software.
|
|
|
|
|
|
SAXS/SWAXS/GISAXS for the routine bio-nanoanalytical laboratory.
Experience revolutionary X-ray point-focussing optics (from Xenocs, Grenoble), extraordinary high brilliance (exceeds best values published for rotating anodes) and bridge the gap to synchrotrons with the Hecus S3-MICRO.
Applications:
* protein solution SAXS
* nanoparticle sizing
* thin-film structure analysis
* LC phase mapping
* nanopowder porosity
Compact & Economical. The compact S3-MICRO System fits into every laboratory. It is powered by an X-ray microsource that operates at a maximum of 50 Watt electrical power, as compared to the several Kilowatts needed for customary x-ray generators (or Megawatts at synchrotrons), most of which had to be cooled away at high cost, also to the environment. Up to 10K Euro annual savings in energy and cooling can be achieved with this Hecus solution.
Fast, Easy & Precise. The S3-MICRO offers a balanced integral design of source, optics and detectors. The ideal SAXS optics – true point focusing optics – makes desmearing a thing of the past: the results are free of optical distortions and readily available for quality assessment (no mathematical corrections are necessary). This enables the measurement of anisotropic, oriented materials and enhances the potential for precise validation, laboratory automatisation and applications in real-time, on-line process control.
Flexible & Modular. The system allows for a wide range of conditions and sample environments, e.g. temperature, pressure, controlled gas atmosphere. A variety of 1D- and 2D-detectors are available (PSD-50M, CCD or solid state pixel detector).
|
|
Hecus – the innovation factory for nanoanalytical systems – now offers the latest camera system for SAXS/SWAXS/GISAXS measurement: the S3-MICROpix (the well-known S3-MICRO with the Pilatus 100K pixel detector (Dectris, CH)).
Revolutionary x-ray point-focussing optics combined with the versatile detection system Pilatus 100K allow for highest brilliance, economy and ultimate performance of the X-Ray camera.
This system stands for:
* even shorter measurement times
* easy handling
* zero background and ultimate linearity
Ultimate performance is the outcome of the combined knowledge and skills of Dectris and Hecus. The S3-MICRO with the Pilatus 100K-detector is now available and impresses with power, speed and compactness.
|
|
Small angle scattering X-ray diffraction
For most people these two names or acronyms mean absolutely nothing. But in the field of X-ray diffraction the interest in Small Angle and Wide Angle X-ray Scattering is becoming of major importance.
In that it enables the researcher to measure parameters relating to characteristics of textured samples with small crystallites with dimensions of perhaps tens of nanometres.
|
|
|
|
|
|
NANOSTAR
NANOSTARThe materials scientists and engineers of today are able to understand and influence the properties of materials on a nanoscale level. Exciting new materials such as designer polymers and bioceramics are being made, and continuing advances with materials such as liquid crystals, metal-organic and thin film coatings are made possible by investigating and altering their nanostructures. A reliable, economic and non-destructive method for analyzing nanostructured materials is SAXS (Small-Angle X-ray Scattering). SAXS yields information such as particle sizes and size distributions from 1 to 100 nm, shape and orientation distributions in liquid, powders and bulk samples.
Another field of interest for SAXS application is the study of biological macromolecules (Bio-SAXS) since the scattering profile contains information about their size, shape and internal structure. This allows for the calculation of relevant structural parameters such as the molecular volume, the molecular mass or the radius of gyration.
The Bruker AXS NANOSTAR, with its intense, collimated primary beam and 2-dimensional detector, has a similar design to a synchrotron SAXS beamline. With a 2-dimensional detector, the misinterpretation of data due to a 0-D or 1-D data collection method is avoided, eliminating the need for restrictive initial assumptions about the sample. In fact, the NANOSTAR analyzes pure sample properties, even if the sample particles are asymmetric or show preferred orientation. Additionally, a real space image with µm SAXS resolution of the sample can be taken by performing Nanography.
|
|
This high-resolution SWAXS system was particularly designed for real-time, simultaneous small- and wide-angle measurements on powders, liquid crystals and polymeric nanomaterials.
The System3 Small- and Wide-Angle X-Ray Scattering (SWAXS) Camera basically has the same specifications as the SAXS-system. However, it is equipped with an additional wide-angle x-ray (WAXS) detector covering an angular WAXS range from 18° to 26° (other ranges on request).
During simultaneous SAXS/WAXS measurement, the data acquisition of both, SAXS and WAXS detectors, is electronically multiplexed with an adjustable ratio.
|
|
|
|
|
|
Gemini A Ultra
Oxford Diffraction, now a part of Varian, Inc., produces a large range of systems used in small molecule crystallography.
Gemini A Ultra
The ideal fast data collections on small molecules and proteins
The Gemini A Ultra system is a complete, turn-key X-ray system designed as part of a unique range of X-ray systems for both small molecule and protein applications. Ideal for fast high resolution small molecule data collections, protein screening and the study of small weak proteins, the Gemini A Ultra is up to 3.5 times faster than the equivalent Gemini R Ultra.
Built around Oxford Diffraction's 4-circle kappa platform, the Gemini A Ultra is mounted with a 135 mm diagonal Atlas CCD detector (2:1 demagnification and 2k x 2k Kodak 4-port CCD chip) and co-mounted Enhance (Mo) and Enhance Ultra (Cu) X-ray sources. The Enhance Ultra providing a rotating anode alternative high brilliance copper X-ray source.
System Build:
- 135 mm Atlas CCD detector
- Enhance (Mo)
- Enhance Ultra (Cu)
- 4-circle kappa platform
The system is also supplied with the following:
- Full safety cabinet
- PC + LCD monitor
- CrysAlisPro (data collection and processing software)
- X-ray tube water chiller
- CCD Chiller
- Installation, training, service and support
|
|
Benchtop X-ray diffractometer
EQUINOX 1000 X-ray Diffraction Systems employs a unique patented curved detector that replaces the conventional scanning goniometers used on other commercial instruments.
This unique detector is able to measure all diffraction peaks simultaneously. It eliminates the need for mechanical scanning devices and does no require complex scanning goniometers used in most other X-ray diffraction instruments.
EQUINOX 1000 is therefore :
Simple to use
Very reliable
Extremely accurate
Superb resolution
|
|
| ... products without technical information |
| |
|
|