AIR-OIL HEAT EXCHANGERS WITH ALTERNATING CURRENT ELECTRIC FANS - SERIE AP:
Today the use of air in hydraulic equipment is more and more common.
The benefits are: No water supply required Totally independent of plummed systems Reduced running costs in comparison with the water-oil exchangers, even if initial investment is higher
Residual warm air can be used for heating
With air-oil heat exchangers the radiator unit is of aluminium for minimum conduction.
|
|
HA Serie:
Standard air-oil combined two-circuit heat exchangers used for cooling compressors from 7.5 to 160 kW. Radiator in aluminium alloy, vacuum braze welded, with high-efficiency turbulators on the air side. Power supply of fan only in AC, blowing ventilation.
|
|
SELF-CONTAINED COOLING UNITS:
The RAS cooling units were engineered and manufactured to substitute the former GAR and OCS series with an uncomplicated and compact product. The units are made up of an aluminium air-oil exchanger and a single electric motor which operates both the oil circulation gear pump and the cooling fan.
|
|
Complete "active coolers" starting with 7 mm overall height up to 46,5 mm height.
The "smallest" is well known in the field of embedded PC´s and the "big-one" from SEPA® is suitable for socket 370-processors with max. 50W CPU heat dissipation
|
|
|
|
|
|
Most installations are sized according to maximum temperatures occurring only rarely during the year, this being exacerbated by the heat-wave phenomenon of recent years, implying over-sizing and therefore a larger footprint, higher sound levels and greater investment in terms of non-productive exchange surfaces.
Adiabatic air coolers provide a response to this type of climatic constraint:
in effect, this system retains the advantages of a dry air cooler, that is where the process circuit is closed, retaining the quality of process fluids without atmospheric pollution or the development of bacteria.
This process, exclusive to GEA, enables the air inflow to be charged with water and therefore its temperature lowered. Mains water is sprayed through nozzles mounted on booms, the position and angle of dispersion of which have been designed so as to charge the air with water efficiently and make maintenance easier.
Water consumption remains limited because spraying only operates at the hottest times of the year thanks to a system of regulation.
Since adiabatic air coolers do not have a tank to collect the water and no water treatment is required, they comply with current legislation concerning protection against legionella bacteria and other proliferations.
This concept avoids the over-sizing of air coolers, and therefore reduces the dimensions of the exchanger, reduces the amount of power used by the fans, as well as the sound level of the installation.
|
|
The environmentally friendly cooling
+ maintenance-free
+ cooling performances 700...4000 W (L35/L10)
+ space-saving ex /internal & top mounting
+ 19"-units
+ Microprocessor controls
+ environmentally friendly
|
|
|
Every energy demand is unique, as is every energy-efficiency improvement opportunity. At Anguil, our track record includes an ability to blend time-tested, standard products with innovative, custom engineered solutions. We design, manufacture and install energy recovery systems that decrease your energy consumption, reduce operating costs and maximize return on investment.
|
|
SP MT Heat Exchanger with 409 Stainless Steel Sinusoidal Plates offers a lower-cost way to capture the exhaust from your low to medium temperature/low pressure baking, drying, heating or other processes – even RTOs and some industrial boilers – and turn it into energy to run other processes, or heat your building.
SP MT Offers Excellent Payback. Improved plant efficiencies. Energy savings. Incredible reductions in costs. Payback periods as short as 6 months-installed.
|
|
COMMON FEATURES
When the external temperature is lower than the internal
temperature and a “maintenance free ” system is requested, a
X-LINE air to air heat exchanger is the most convenient choice.
The air to air heat exchanger XVA, with the internal patented
aluminium core, satisfy completely the market request by small
dimensions, very high efficiency and new design.
Four sizes from 16 W/K to 85 W/K heat transmission rate.
They are always supplied with deflectors for the outlet of ambient and enclosure air in order to optimize the enclosure thermal management.
|
|
|
|
|
|
|
AAF has long recognized the need for a new type of gas cooling device, one that not only cools process gases, but one that could be designed to recover the heat to be used in other processes. It was with these objectives that AAF developed the Forced Air Cooler (FAC), or air to air heat exchanger, and now has over 50 of them installed worldwide, either operating or under construction. The FAC can be used for cooling kiln or preheater gas and clinker cooler gas. It has several advantages over conventional methods of cooling by U-tube coolers, water spray towers, and cooling by dilution air. The FAC is compact and can be fitted into spaces where a U-tube cooler will not. It can be designed to maintain a constant outlet temperature, independent of the ambient air temperature. It cools the gas without adding to the volume, unlike dilution cooling and water spray cooling. The tube bundle section can be shipped in one piece, thereby reducing field installation costs. A thermocouple mounted in the FAC outlet duct controls the fans as required to maintain a constant outlet temperature. Several different duct arrangements are available, including top entry, bottom entry, and side entry.
|
|
Heat
AIR-TO-AIR HEAT EXCHANGER
In the event where process air is to be separated from combustion air:
Increased efficiency
Refractory stainless steel body
Stainless steel unit
Power from 140 to 340 kW
Operating temperature 170 °C max.
|
|
Seifert has three types of insert cooler for 19" cabinets in heights of 2 to 6 HU: filterless air conditioners (KG), air/water (RK) & air/air heat exchangers (LT). The units draw the ambient air in from either the back or front of the cabinet. The assembly system ensures easy integration in 19"-electronic systems. High quality tried & tested components ensure smooth operation & a long working life.
filterless maintenance-free
cooling performances 1000/2000 W (L35/L35)
reliable insert-system
air conditioners in 6 HU
heat exchangers air/water in 2/4 HU
heat exchanger air/air in 4 HU
|
|
Unlike typical chillers, General Air Products' chillers have been designed specifically for industry. The fruit
of over 20 years in the industrial chilling market, with hundreds of thousands of refrigerating machines installed
worldwide, General chillers perfectly match the needs of a diverse range of industries
|
|
Coolers reduce the temperature of the hot gases in the installations.
Thus they allow the reduction of the quantity of dust-laden gas to be treated and therefore the minimisation of the size of the dust extractors installed downstream.
|
|
Air cooling
Cooler Series DN025...DN300
Air-cooled aftercoolers, serving all compressor sizes
Features
* Complete units including cooler, fan, motor, shroud and guard
* Air volume flow range 5 l/s...400 l/s
* Working pressure up to 15 bar
* Suitable for cooling and partial drying of compressed air
* Approach temperature 1 K...20 K
Benefits
* Compact, low weight and efficient cooling systems
* Completely assembled for easy installation
* Delivery times on request
* High reliability and long lifetime of a modern quality product
* Qualified series-product with worldwide approvals
|
|
Off line oil / air blast cooler BNK series
Integrated circulation pump
Low noise emissions
Easy to maintain
By-pass also available
High performance off-line coolers with compact dimensions, motor with two spindles for pump and fan. Matrix easy to dismantle.
|
|
|
|
|
|
Oil/air heat exchangers
type LKI
Low noise level
High performance
Low cost
Product description
With this new generation of Universal Hydraulik LKI oil-coolers, the manufacturers have succeeded in reducing the noise level. These coolers are ideally suited for stationary installations - for the cooling of hydraulic or lubricating oils. The range has been extended to include slow-running ventilators, and the housings have been optimised, in order to produce the very low noise level. In order to make the cooler range as comprehensive as possible, the smaller models are also available as single or dual versions, thus covering oil-cooling requirements for both low and high oil throughflow volumes.
Product features
Testing pressure: 26 bar static according to DIN 50104
Operating pressure: 16 bar
(min. 2 Mill. Cycles from 0-16 bar at 2 Hz and 60 °C)
Compact oil-cooler
High operating pressure
High cooling performance
Low pressure loss
Max. operating pressure: 120 °C
High flexibility
2" SAE flange from LKI 700 upward
Also for use with water/glycol
Variable motor; Hydro / 12/24V
|
|
|
|
|
|
Airtech Aluminum Fan Cooled Units
Our line of Airtech Fan Cooled Heat Exchangers provides a standardized, reliable and self-contained solution for remote cooling requirements in both the Industrial and Mobile Vehicle markets. These compact, high efficiency Oil Coolers and Aftercoolers can be the perfect answer for applications where cooling requirements are remotely located, cooling water is unavailable or impractical, or where coolants may be subject to freezing.
These pre-engineered packages include an all-aluminum vacuum brazed bar & plate heat exchanger for superior durability and performance in a cost-effective, compact, light weight construction. Motors can be supplied in either 60 hertz or 50 hertz AC versions, or 12 volt DC versions. Both come complete with finger guard and shroud.
Our product range encompasses 11 different model sizes. The first 8 sizes are vertical mounts with horizontal air flow, while the three largest sizes are horizontal mounts with vertical air flow. The units come with a variety of standard options, ensuring our customer gets what they need with very short lead-times.
|
|
AC Industrial Coolers (LAC) - Coolers with AC motors for industrial hydraulic systems
The LAC air oil cooler with single-phase or three-phase AC motor is adapted for use in the industrial sector.Together with a wide range of accessories, the LAC cooler is suitable for installation in most applications and environments. The maximum cooling capacity is 160 kW at ETD 40°C. Choosing the right cooler requires precise system dimensioning. The most reliable way to dimension is with the aid of Oiltech’s calculation program. This program, together with precise evaluations from our experienced, skilled engineers, gives you the opportunity for more cooling per pound invested.
|
|
cooling power:1-250KW
application:hydraulic and lubrication oil cooling system
working pressure:10-26Bar.
Dc or AC drive
|
|
The first choice for oil cooling in hydraulic circuits.
Your Advantage
The correct cooling solution offers a longer oil life, i.e. lower maintenance and change frequency. A constant oil temperature also means improved machine precision.
AKG-Range T1 - T 11... maximum working pressure 26 bar
AKG-Range TL1 - TL 6 ... maximum working pressure 14 bar
|
|
ASA 0177
- Working pressure (static): 26 bar (370 PSI)
- Radiator material: Aluminium
|
|
Air/Oil standard heat exchangers
The range of air/oil heat exchangers has proved to be extremely reliable for a number of different hydraulic oil cooling requirements using the air generated by electric fans, hydraulic fans or, in the industrial sector, by single-phase and three-phase electric fans. The availability of models has now been further extended in order to satisfy all requirements.
|
|
New LAC2 air/oil coolers with AC motor
Up to 20 % higher cooling capacity 160 Kw. The LAC2 cooler is suitable for installation in most applications and environments.
Economic and environmental benefits
- The hydraulic system’s and oil’s useful life is extended
- The hydraulic system’s availability increases, more operating time and fewer shutdowns
- Service and repair costs are reduced
- High efficiency level maintained in continuous operation.
|
|
Air-Oil heat exchangers have been designed to be used on the return line of the hydraulic systems.
The radiating mass is made of aluminium alloy, nominal pressure of 25bar and max Temperature 120C.
In addition to the standard SS and ST series, there are the SS2/ST2 double pass series for a higher heat exchange and SD/SDT series for higher flows (up to 320 L/min).
|
|
HY Serie:
Standard oil-air heat exchangers used for the cooling of industrial systems and mobile machines. Radiator in aluminium alloy, vacuum braze welded, with high-efficiency turbulators on the air side. Power supply voltages of fan AC, DC or with activation by means of hydraulic motor. Intake fan for better cleaning of the radiant package, anti-vibration supports always included.
|
|
|
Lytron's ES Series aluminum oil coolers are engineered for high performance with poor heat transfer fluids such as oils and EGW. The extended surface flat tube design provides 2.5 times better performatnce than competitive units. The unique flat tube and header designs result in lower pressure drop so smaller, less expensive pumps can be used. Welded headers are pressure tested to 150 psi (10.3) bars and the fluxless, vacuum-brazed core provides strength and reliability. The Aluminum Oil Coolers are available with or without a fan plate, and with finish options of aluminum or black paint.
|
|
AKG C and CP Coolers
Oil/compressed air combination coolers for screw compressors with up to 110 kW driving power. Proven AKG cooler models used worldwide. Trust the experience of AKG as the market leader for the cooling of compressors.
CP-Series... for high duty applications in medium and upper performance classes up to 110 kW
C-Series... for medium duty applications in lower performance classes up to 30 kW
|
|
ASA 0115 :
- Pression de service (statique): 26 bar
- Matière de l'élément refroidisseur: Aluminium
|
|
|
RFC and RFI chillers are used for cooling of little process and machines. With pump and tank intergrated they are very compact and easy to use.
|
|
|
|