Power Break II Insulated Case Circuit Breakers are highly compact, heavy-duty breakers that combine ease of use, asethetics and state-of-art performances in 200 through 4000-Amp frame sizes, rated for up to 200,000 Amps RMS symmetrical for 240Vac, in drawout and stationary versions.
Now available with the new EntelliGuard® TU Trip Unit which provides excellent selectivity and arc flash energy protection.
Features and Benefits
* Compact, Lightweight design
* Modular, drop-in accessories common to all frame sizes
* Flush-Mounted pump handle
* Manually and electrically operated versions in same compact envelope
* Double Insulated ON/OFF buttons
* 72-point pre-wired , dedicated secondary terminals
* Modular, field-installable motor operator
* EntelliGuard TU Trip Unit featuring Reduced Energy Let-Through (RELT) setting
* Modular auxiliary switches with up to 12 NO/NC set of contacts
* Charge-after-close mechanism
* Manual discharge of springs without closing
* Suitable for reverse feed™
|
|
|
|
|
|
High Performance Circuit Breakers:
410
Thermal-magnetic circuit breakers,
various mounting methods, toggle operated
412
Thermal circuit breaker with threadneck
mounting and push-pull actuation
413
Thermal circuit breaker with threadneck
mounting and push-pull actuation
428
Thermal-magnetic circuit breaker,
plug-in type, with manual release button
437
Thermal-magnetic circuit breaker
with remote trip coil, toggle operated
446/447/449
Thermal-magnetic circuit breaker, base
mounting, special dual button manual release
452
Thermal-magnetic circuit breaker with
threadneck mounting and push-pull actuation
482
Thermal circuit breaker with threadneck
mounting and push-pull operation
483
Thermal aircraft style circuit breaker,
temperature-compensated and explosion-proof
4120
Thermal circuit breaker with threadneck mounting, temperature-compensated and explosion-proof
4140
Thermal circuit breaker with threadneck mounting, single pole, robust design
4930
Remote control circuit breaker, single pole, temperature-compensated
5140
Thermal circuit breaker with threadneck
mounting, three-pole, robust design
520/530
Thermal-magnetic circuit breaker with toggle actuaction, double pole (520) or three-pole (530)
583
Thermal circuit breaker with threadneck mounting, temperature-compensated and explosion-proof
|
|
Circuit Breaker and Transient Voltage Surge Suppressor
The Siemens circuit breaker and transient voltage surge suppressor is comprised of a highly effective TVSS module integrated with (2) 1-pole circuit breakers. This device incorporates the robust features of our secondary circuit breaker surge arrester with a lower clamping voltage ratings.
Two red LED indicator lights are provided to show that surge protection is provided for all circuits connected to the panelboard. As a Siemens exclusive feature, the device notifies the owner of loss of surge protection by tripping one or both of the circuit breakers. These breakers should be used for circuit protection of frequently used household or facility circuits because the lights and devices connected to these circuits provide an effective indication that surge protection is being provided.
|
|
|
The "Record Plus" family of circuit breakers has been developed as a line of aesthetically and technically coordinated protection devices for LV distribution and control applications.
|
|
RCCB Record Plus: FD63/160 frame size
Rated at 160A, the FD63/160 frame size is designed for use in both a DIN-rail environment with modular equipment and in industrial applications. It is supplied with IPXXB terminals suitable for direct connection of one or two conductors totalling up to 95 mm² and is available as a thermal-magnetic breaker, a moulded case switch, and as a magnetic-only motor circuit protector.
The FD63/160 bridges the gap between residential miniature circuit breakers and industrial moulded case circuit breakers.
In compliance with EN 60947, BS, VDE, UTE, KEMA, CEI
3 and 4 pole versions available
FD63 to 63A and FD160 to 160A
Full range of add-on accessories, including:
thermal magnetic/magnetic trip units
auxiliary contacts
completely integrated add-on devices available
rotary handles
electrical operators
connectivity - 60 mm system
|
|
Description
Special technical features of dead-tank design. The distinguishing feature of dead-tank technology is that the interrupter chamber is accommodated in an earthed metal housing. With this arrangement the SF6 gas filling insulates the high voltage live parts of the contact assembly from the housing. Outdoor bushings connect the interrupter chamber with the high-voltage terminals.
|
|
Siemens high-voltage circuit-breakers offer the optimum technical and economical solution for every requirement. Depending on the application and the voltage level, they are equipped with the following combinations of arc quenching principle and operating mechanism:
* Self-compression principle with stored energy spring mechanism
* Puffertype with hydraulic mechanism
All the live- and dead-tank circuit-breakers, as well as the gas-insulated switchgear (GIS), are equipped with the same components. Longevity, reliability and highest availability in all climate zones in the world distinguish Siemens high-voltage circuit-breakers from all others.
|
|
Description
Special technical features of live-tank design: On live-tank circuit-breakers, the interrupter chamber is arranged in the insulator which can be either porcelain or of a composite material, and is at high potential; with the voltage level determining the length of the insulators for the interrupter chamber and the insulator column.
|
|
|
|
|
|
SIPROTEC 7SV600 is a numerical relay used for circuit-breaker failure protection. It is suitable for use at all voltage levels and in all applications.
Protection functions
• Circuit-breaker failure protection (single or three-pole with/without current)
• Independently settable delay times for operation with and without current
• Single or two-stage time delay of the busbar trip command
• Re-trip (cross trip) stage (1st stage of the 2-stage operation)
• Intertrip facility (via teleprotection interface)
• End-fault protection with intertrip
• “No current” control using the circuit-breaker auxiliary contacts
Features
• Highly sensitive current detection
• 2-out-of-4 check of the current detectors
• Short reset time, negligible overshoot time
• Can be initiated by phase-segregated or common-phase trip commands
• End-fault protection
• Assignable output relays, LEDs and binary inputs
Monitoring functions
• Monitoring of circuit-breaker auxiliary contacts
• Operational current measured values
• Self-supervision of the relay
• Event buffer
• Fault protocols
• Oscillographic fault recording
|
|
Siemens high-voltage circuit-breakers offer the optimum technical and economical solution for every requirement. Depending on the application and the voltage level, they are equipped with the following combinations of arc quenching principle and operating mechanism:
* Self-compression principle with stored energy spring mechanism
* Puffertype with hydraulic mechanism
All the live- and dead-tank circuit-breakers, as well as the gas-insulated switchgear (GIS), are equipped with the same components. Longevity, reliability and highest availability in all climate zones in the world distinguish Siemens high-voltage circuit-breakers from all others.
|
|
High inrush currents with AgSnO contacts (TV4 = 65 A)
4 kV/8 mm coil-contact
Reinforced insulation (protection class II)
Ambient temperature up to 85°C at 8 A
Plastic materials according to IEC60335-1 (domestic appliances)
RoHS compliant (Directive 2002 / 95 / EC) as per
Applications
HVAC, interface technology, power supplies, TV-/Monitor control,
computer-/communication technology, domestic appliances, Hi-Fi
products, timers, etc
|
|
7PA30 single phase is for the supervision of the trip circuit of a circuit breaker with one trip coil. While 7PA30 three phase is for the supervision of the trip circuit of a circuit breaker with three selective trip coils.
The trip circuit wiring is supervised from the positive supply to the negative supply whilst the circuit breaker is open or closed.
The design, quality and rugged construction of the relay make it suitable for applications requiring high levels of reliability/dependability.
The high degree of protection guarantees reliable operation over a wide temperature range, even under extreme environmental conditions. The relay has been tested in accordance with IEC, EN and IEEE standards. The relay is CE marked.
The supervision current is always less than 1,4mA thus avoiding unwanted operation of the trip coil. Correct operation is shown via a green LED.
|
|
|
|