Cover Assemblies for Spirax Sarco Float & Thermostatic Steam Traps
Different features available
|
|
Automatic valves for the discharge of condensate without discharging steam.
Operating Pressure Range: Vacuum - 3700 psig
Operating Temperature Range: 32 - 1022 °F
A steam trap is a kind of automatic valve that discharges condensate generated during processes and in steam transport lines, without allowing the discharge of any steam. Steam trap operation principles can be roughly divided into three categories. TLV manufactures all three of these categories.
An extensive product line-up makes it possible to select the optimal product to suit the objective or application.
Each trap offers the highest level of energy conservation in its class.
Much consideration is given to the aspect of maintenance, as evidenced by designs that include the unitization of parts, interchangeable parts, and utilization of re-useable PTFE gaskets.
|
|
- For large high capacity units
- Sizes available:
Series C:
11/4" NPT and BSPT
11/2" NPT and BSPT
2" NPT and BSPT
21/2" NPT
Series X:
2" NPT
- Resistant to water hammer and corrosion
- Below condensate level seat design prevents steam leakage
- Rugged stainless steel thermostatic element eliminates air binding
- Stainless steel internal components
- Can be serviced without dismantling piping
- Maximum operating pressure 175 psig (12.1 bar)
- Maximum temperature 377°F (192°Cl
|
|
Remove condensed oil and water from your compressed air system with condensate drain valves from Pneumatic Products. Durability and reliability are offered with a complete line of fully automatic types including: float, timer actuated, no-air-loss and motorized ball valves. Drain valves should be installed at each liquid collection point of a compressed air system including the receiver, aftercooler, coalescing filters and wherever drip-legs are installed. The installation of drain valves will ensure a compressed air system free from the damaging effects of liquid and sludge.
|
|
Features:
- operates in accordance with the actual condensate quantity
- avoids unnecessary loss of compressed air
- is equipped with a fault signal
- has large cross-section value to prevent emulsification
|
|
Pressure up to 16 bar, temp. range: 1 - 60°C
C A P A C I T Y
Model compressor refrigeration Filter Connection
aftercoooler dryer
ED2002 --- --- 720m³/h G 3/8
ED3004 240 m³/h 480 m³/h 2,400 m³/h 1 x G 1/3, G 1/8
ED3007 420 m³/h 840 m³/h 4,200 m³/h 2 x G 1/2, G 1/8
ED3030 1,800 m³/h 3,600 m³/h 18,000 m³/h 2 x G 1/2, G 1/8
ED3100 6,000 m³/h 12,000 m³/h 60,000 m³/h 2 x G 1/2, G 1/8
Standard version with BSP thread (G) for 230V/50 - 60Hz supply voltage. Alternatively versions NPT thread (N) or 115V/50 - 60Hz or 24V/50 - 60Hz available. 24V DC on request
ecodrain 2000, for pressure up to 50 bar, temp. range 1 - 60°C, intern. heater available!
C a p a c i t y
Model Compressor Refrigeration Filter 2* Connections
aftercooler dryer
ED2010 1,290 m3/h 2,580 m3/h 12,900 m3/h 2 x G 1/2
ED2020 6,000 m3/h 12,000 m3/h 60,000 m3/h 3 x G 3/4
ED2060 66,000 m3/h 132,000 m3/h 660,000 m3/h 3 x G 3/4
|
|
|
It is globally recognised that condensate from oil-injected compressors is an oil-water emulsion, classified as oil residue and must not be drained into the sewage system nor into the environment. Legislation, worldwide, has become more and more stringent as to the disposal of this oily waste water.
|
|
It is globally recognised that condensate from oil-injected compressors is an oil-water emulsion, classified as oil residue and must not be drained into the sewage system nor into the environment. Legislation, worldwide, has become more and more stringent as to the disposal of this oily waste water.
With the introduction of the OSM 500 and 900 oil-water separators, with the latest filter membrane technology, Atlas Copco offers a most cost effective, safe, environmentally friendly and simple system to handle condensate from oil-injected compressors, fully in compliance with governmental regulations.
|
|
The range of EWD electronically controlled condensate drains is synonymous with safe, dependable and economical condensate management.
The intelligent drain function monitors condensate build-up with liquid level sensors and evacuates the condensate only when necessary, thus avoiding wastage of compressed air and giving considerable energy savings.
The EWD drain device offers security and confidence, enabling you to solve all condensate discharge problems even with heavily contaminated systems.
A wide range of different EWD drains is available for oil contaminated condensate and may also be provided with additional hard coating for use with oil-free and aggressive condensate.
|
|
Condensate Drains
Remove condensed oil and water from your compressed air system with condensate drain valves from Pneumatic Products. Durability and reliability are offered with a complete line of fully automatic types including: float, timer actuated, no-air-loss and motorized ball valves. Drain valves should be installed at each liquid collection point of a compressed air system including the receiver, aftercooler, coalescing filters and wherever drip-legs are installed. The installation of drain valves will ensure a compressed air system free from the damaging effects of liquid and sludge.
|
|
Kaeser's Eco-Drain Series of electronic condensate drain traps efficiently eliminate moisture from the compressed air system. They are ideally suited for equipment such as dryers and filters. The capacitance sensor technology ensures that only condensate is released - not valuable compressed air.
Important features and advantages:
Reliable condensate removal in a variety of industrial and commercial environments
Wear-free, capacitance level sensor
Electronically controlled diaphragm valve releases condensate not compressed air
Patented valve technology protects internal components from contamination even in harsh environments
Simple installation and maintenance
|
|
Collecting and eliminating condensates is an active part for improving the quality of your air production.
An efficient drain system eliminates completely the risk to have condensate water in your air network and pneumatic installation.
It is a guarantee of increased lifetime of your equipment and less production rejects.
|
|
The range of EWD electronically controlled condensate drains is synonymous with safe, dependable and economical condensate management.
The intelligent drain function monitors condensate build-up with liquid level sensors and evacuates the condensate only when necessary, thus avoiding wastage of compressed air and giving considerable energy savings.
The EWD drain device offers security and confidence, enabling you to solve all condensate discharge problems even with heavily contaminated systems.
A wide range of different EWD drains is available for oil contaminated condensate and may also be provided with additional hard coating for use with oil-free and aggressive condensate.
|
|
Mechanical Demand Operated
Drain Valves
Reliable and economical, mechanical demand operated drain valves do not waste any valuable compressed air. They detect the presence of liquid and only operate when filled to a pre-determined level. Upon actuation, they discharge only liquid and close before any compressed air can be exhausted. Fully automatic, mechanical demand operated drains do not require electricity to operate.
|
|
| ... products without technical information |
| |
DRAIN-LINE HEATERS - FLEXDRAIN® CSC2K
Silicon elastomer insulated drain-line heaters with integrated thermostat
CSC2K heaters are designed to be placed at the bottom of collector trays inside refrigeration equipment in cold rooms, to prevent freezing and to allow condensate water to flow freely.
The integrated thermostat makes them fully autonomous.
Note: The most commonly used power rating is 50 W/m. However, for plastic trays, we strongly recommend using the 40W/m range.
TECHNICAL CHARACTERISTICS :
- Integrated thermostat.
- Fully sealed.
- Double insulation.
- Extremely flexible.
- Voltage 230 V as standard.
- Power cable: length 1 m as standard.
|
|
|
|