Ground fault pressure transmitter / with digital output
max. 40 psi | 885 series Celmi

CONSTRUCTIVE CHARACTERISTICS:
-Accuracy: ±1% F.S.O.
-Stability: +/- 0,5% F.S.O./yr.
-Thermal effects Zero: +/- 0,075% F.S.O/°C (0,5" Range) +/- 0,120% F.S.O./°C
-Termal effects span: +/- 0,01% F.S.O/°C
-Over pressure: 20Psi or 2X FSP, whichever is greater
-Pressure range: 0,1 WC to 40 PSI (custom or Bi-Directional ranges available)
-Compensated range: 10° to 50°C (50° to 122° F)
-Media: Limited only to media that will not attack polyphenylene sulphide (PPS), polyetherimide (PEI), silicone RTV. Note that liquids are allowed in either or both ports.
-Operating Hhumidity: 90% RH, non-condensing
-Operating Temp.: -25° to 70° C (-13° to 158° F)
-Input supply: 14-36 VDC/24 VAC
-Maximum loop resistance: VS-14 x 50 ohm Max
-Minimum loop resistance for supply voltage>30VDC: VS-30 X 40 ohm Minimum
-Load resistance: 2 Kohm minimum on voltage out, 250 ohm maximum loop resistance on 4-20mA (500 ohm maximum loop resistance on 4-20mA upon request)
-Output signal: 4-20mA 2-wire - Adjustments: Offset 60% of F.S.O. minimum
-Electrical connections: Pluggable screw terminal block
-Pressure connections: Brass Barbed fitting for 1/8" I.D. id tubing
-Housing: Impact resistance ABS plastic
-Dimensions: Approx. 3,5" x 2,7" x 1,4" (8,7cm x 6,8cm x 3,5cm)
-Display: 0,38" Height

{{requestButtons}}
Favorites

Other Celmi products

Pressure sensors

Off center

Compression low profile

Compression column

Tension and compression

Shear beam

Double shear beam

Bending beam

Pin

Special load cells

Instruments

End products

Strain gages